{"title":"Electronic Tools \u0026 Gadgets","description":"\u003cp\u003eShop our electronics .\u003c\/p\u003e","products":[{"product_id":"ut8805e-5-5-digit-performance-series-bench-digital-multimeter","title":"UT8805E 5.5 Digit Performance-Series Bench Digital Multimeter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UT8805E Performance-Series Bench Digital Multimeter\u003c\/strong\u003e is a \u003cstrong\u003e5½-digit auto-ranging True-RMS\u003c\/strong\u003e meter with \u003cstrong\u003e0.015% basic DC voltage accuracy\u003c\/strong\u003e, a \u003cstrong\u003e5,000 rdgs\/s\u003c\/strong\u003e maximum reading rate, and a \u003cstrong\u003e199,999-count\u003c\/strong\u003e display on a \u003cstrong\u003e4.3in 480×272 TFT-LCD\u003c\/strong\u003e. SCPI over LAN, RS-232, and USB makes the UT8805E a clean drop-in for automated test setups.\u003c\/p\u003e\n\u003cp\u003eFor R\u0026amp;D measurement and small-lab production test where SCPI automation, \u003cstrong\u003efour-wire (Kelvin) resistance\u003c\/strong\u003e, \u003cstrong\u003edual display\u003c\/strong\u003e, and the full math\/dB\/dBm\/Pass-Fail suite matter, the UT8805E delivers the performance jump from general-purpose bench DMM to instrumented test station. Four display modes (Number, Bar Graph, Trend Graph, Histogram), thermocouple and RTD temperature measurement, and 10,000-reading internal storage are standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5½-digit, 199,999-count display\u003c\/strong\u003e — 0.015% basic DC voltage accuracy at the tier price point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS AC measurement\u003c\/strong\u003e — accurate readings on non-sinusoidal waveforms (switching supplies, motor drives, PWM, dimmed loads).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-ranging\u003c\/strong\u003e — across voltage, current, resistance, and capacitance functions, reducing operator workflow friction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5,000 rdgs\/s maximum reading rate\u003c\/strong\u003e — fast acquisition for high-throughput automated test and noise-reduction averaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple and RTD temperature measurement\u003c\/strong\u003e — range -270°C to 1820°C, with built-in cold-end compensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-wire (Kelvin) resistance measurement\u003c\/strong\u003e — eliminates lead and contact resistance from low-resistance readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual display\u003c\/strong\u003e — simultaneous viewing of two parameters (e.g., voltage + frequency) without menu toggling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMath, statistics, and Pass\/Fail\u003c\/strong\u003e — max\/min\/average, standard deviation, dB\/dBm, relative, configurable limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour display modes\u003c\/strong\u003e — Number, Bar Graph, Trend Graph, and Histogram.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLAN, RS-232, USB-Host, USB-Device\u003c\/strong\u003e — SCPI command set, VXI-11, USBTMC for full remote-control automation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10,000 readings internal storage\u003c\/strong\u003e — measurement files, instrument setups, and SCPI logs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UT8805E Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e5½-Digit Display and 0.015% Accuracy\u003c\/h3\u003e\n\u003cp\u003eThe UT8805E delivers a \u003cstrong\u003e5½-digit 199,999-count\u003c\/strong\u003e display with \u003cstrong\u003e0.015% basic DC voltage accuracy\u003c\/strong\u003e. DC voltage resolution reaches \u003cstrong\u003e1μV\u003c\/strong\u003e and DC current resolution reaches \u003cstrong\u003e1nA\u003c\/strong\u003e — meeting the spec floor required for low-signal R\u0026amp;D measurement, transducer-output characterization, and reference-source verification. Resistance measurement resolution is \u003cstrong\u003e0.1mΩ\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Display.png\" alt=\"4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Display.png\" alt=\"4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\u003c\/span\u003e\n\n\u003ch3\u003eMeasurement Function Coverage\u003c\/h3\u003e\n\u003cp\u003eMeasurement coverage includes AC\/DC voltage, AC\/DC current, resistance, four-wire resistance, capacitance, diode, continuity, frequency, duty cycle, temperature (thermocouple), period. Capacitance measurement extends to \u003cstrong\u003e2 mF\u003c\/strong\u003e. Frequency counter range is \u003cstrong\u003e20 Hz – 1 MHz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTrue-RMS AC Measurement\u003c\/h3\u003e\n\u003cp\u003eTrue-RMS AC measurement delivers correct readings on distorted, non-sinusoidal waveforms — switching-mode power supply outputs, motor-drive currents, dimmed lighting loads, PWM signals — where an average-responding meter would read low. AC voltage and AC current measurements are both True-RMS.\u003c\/p\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Dual.png\" alt=\"Dual display showing voltage and frequency simultaneously\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eDual display showing voltage and frequency simultaneously\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eDual Display\u003c\/h3\u003e\n\u003cp\u003eDual display shows two parameters at once — voltage with frequency, current with frequency, or any compatible primary\/secondary pairing — without toggling between menus. For diagnostics on AC sources, switching supplies, and motor drives, this lets you watch the primary measurement and its frequency simultaneously.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Dual.png\" alt=\"Dual display showing voltage and frequency simultaneously\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eDual display showing voltage and frequency simultaneously\u003c\/span\u003e\n\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eMath, Statistics, and Pass\/Fail\u003c\/h3\u003e\n\u003cp\u003eBuilt-in math includes max\/min\/average tracking, standard deviation, relative measurement (REL), dB and dBm operations, and configurable limits. Pass\/Fail comparison automatically flags out-of-tolerance readings and sounds an alarm. All math operations apply across voltage, current, resistance, capacitance, frequency, and temperature.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Math.png\" alt=\"Built-in math: statistics, limits, dB, dBm, and relative operations\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in math: statistics, limits, dB, dBm, and relative operations\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Math.png\" alt=\"Built-in math: statistics, limits, dB, dBm, and relative operations\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in math: statistics, limits, dB, dBm, and relative operations\u003c\/span\u003e\n\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Modes.png\" alt=\"Four display modes: Number, Bar Graph, Trend Graph, and Histogram\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFour display modes: Number, Bar Graph, Trend Graph, and Histogram\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eFour Display Modes\u003c\/h3\u003e\n\u003cp\u003eFour display modes adapt the on-screen presentation to the measurement task: \u003cstrong\u003eNumber\u003c\/strong\u003e for a clean primary reading, \u003cstrong\u003eBar Graph\u003c\/strong\u003e for quick visual go\/no-go interpretation, \u003cstrong\u003eTrend Graph\u003c\/strong\u003e for time-series behavior, and \u003cstrong\u003eHistogram\u003c\/strong\u003e for distribution visualization on repeated samples. Switching is a single-key operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Modes.png\" alt=\"Four display modes: Number, Bar Graph, Trend Graph, and Histogram\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFour display modes: Number, Bar Graph, Trend Graph, and Histogram\u003c\/span\u003e\n\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e4.3-inch TFT-LCD with 480×272 Resolution\u003c\/h3\u003e\n\u003cp\u003eThe 4.3-inch TFT-LCD displays the full 199,999-count primary reading with secondary parameter and unit annotations at high legibility from typical bench viewing distance. The digitized analog bar graph beneath the primary reading supports rapid trend interpretation when the measurement is changing slowly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Display.png\" alt=\"4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Display.png\" alt=\"4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\u003c\/span\u003e\n\n\u003ch3\u003e5,000 rdgs\/s Maximum Reading Rate\u003c\/h3\u003e\n\u003cp\u003eMaximum reading rate is \u003cstrong\u003e5,000 rdgs\/s\u003c\/strong\u003e on the UT8805E. For automated test sequences this means short loop times when stepping through measurement steps under SCPI control. For high-resolution characterization, the same reading rate supports averaging-based noise reduction without slowing the test cadence.\u003c\/p\u003e\n\u003ch3\u003eFour-Wire Resistance\u003c\/h3\u003e\n\u003cp\u003eFour-wire (Kelvin) resistance measurement eliminates lead and contact resistance from low-resistance readings. For shunt resistors, motor windings, contactor coils, PCB-trace resistance, and any measurement below approximately 100 Ω where lead resistance distorts the result, the four-wire path delivers the accuracy the digit count promises.\u003c\/p\u003e\n\u003ch3\u003eTemperature Measurement\u003c\/h3\u003e\n\u003cp\u003eTemperature measurement supports thermocouple sensors over the range \u003cstrong\u003e-270°C to 1820°C\u003c\/strong\u003e with \u003cstrong\u003e0.5°C accuracy\u003c\/strong\u003e, plus RTD (thermal-resistance) sensor input for higher-accuracy laboratory measurements. A built-in cold-end compensator is standard, so external reference junctions are not required.\u003c\/p\u003e\n\u003ch3\u003eConnectivity and Remote Control\u003c\/h3\u003e\n\u003cp\u003eFour host interfaces: \u003cstrong\u003eLAN\u003c\/strong\u003e, \u003cstrong\u003eRS-232\u003c\/strong\u003e, \u003cstrong\u003eUSB-Host\u003c\/strong\u003e, and \u003cstrong\u003eUSB-Device\u003c\/strong\u003e. LAN supports VXI-11 for SCPI-over-Ethernet; USB-Device supports USBTMC; RS-232 supports established automated-test scripts and embedded controllers that don't have an Ethernet path. USB-Host accepts a USB flash drive for file import\/export. SCPI command set is IEEE-488.2-style and compatible with the mainstream multimeter command set, easing migration from existing test code.\u003c\/p\u003e\n\u003ch3\u003eSCPI Command Set and Automation\u003c\/h3\u003e\n\u003cp\u003eThe UT8805E accepts SCPI commands compatible with the mainstream multimeter command set, easing migration from existing test scripts. Configuration and triggering via SCPI is supported across all measurement functions. Firmware updates are free over the product's lifetime. Measurement results return as ASCII or numeric blocks per SCPI conventions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Measurement and Characterization\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-resolution DC voltage and current measurement on bench power rails, sensor outputs, and reference circuits.\u003c\/li\u003e\n\u003cli\u003eComponent characterization across voltage, resistance, capacitance, and temperature within a single bench session.\u003c\/li\u003e\n\u003cli\u003eLong-term drift studies with timestamped recording to internal storage and post-test export over USB or LAN.\u003c\/li\u003e\n\u003cli\u003eFour-wire resistance measurement of low-value shunts, PCB traces, and contact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduction Test and Automated Quality Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSCPI-driven automated test sequences with reading rates that keep loop times short on multi-DUT lines.\u003c\/li\u003e\n\u003cli\u003ePass\/Fail comparison automatically flagging out-of-tolerance units with audible alarm.\u003c\/li\u003e\n\u003cli\u003eIncoming-inspection batch testing with statistical summary reporting (max, min, average, standard deviation).\u003c\/li\u003e\n\u003cli\u003eIntegration into existing rack-and-stack production environments via LAN (VXI-11) or USB (USBTMC).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCalibration and Metrology Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerification of bench instruments against reference standards using the meter's high resolution and accuracy.\u003c\/li\u003e\n\u003cli\u003ePeriodic in-house verification of secondary standards between formal calibration cycles.\u003c\/li\u003e\n\u003cli\u003eRTD- and thermocouple-based thermal characterization with cold-end compensation built in.\u003c\/li\u003e\n\u003cli\u003eLong-duration logging of environmental and reference-source drift for trend analysis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT8805E benchtop digital multimeter\u003c\/li\u003e\n\u003cli\u003eStandard test lead set\u003c\/li\u003e\n\u003cli\u003eAC power cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eUSB-Device cable for PC connection\u003c\/li\u003e\n\u003cli\u003ePC software (included; downloadable from uni-trend.com)\u003c\/li\u003e\n\u003cli\u003eUser manual and factory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-wire test lead set\u003c\/strong\u003e — Kelvin-style test leads for low-resistance measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType-K thermocouple probe\u003c\/strong\u003e — for temperature measurement across the supported range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard 19-inch rack mount kit\u003c\/strong\u003e — for rack-integration in production-test and ATE installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8802E\u003c\/strong\u003e — Value-tier 4½-digit manual-range bench DMM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8803E\u003c\/strong\u003e — Classic-tier 3⅚-digit auto-ranging bench DMM with inductance and D\/Q.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8804E\u003c\/strong\u003e — Advanced-tier 4⅚-digit bench DMM with data recording and Pass\/Fail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8805E\u003c\/strong\u003e — Performance-tier 5½-digit SCPI bench DMM with four-wire resistance and math. \u003cem\u003e(this product)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8806E\u003c\/strong\u003e — Performance-tier 6½-digit SCPI bench DMM (LAN\/RS-232\/USB).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8806EG\u003c\/strong\u003e — Performance-tier 6½-digit bench DMM with IEEE-488.2 GPIB (substitutes for RS-232).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the UT8805E compare to other models in the UT8800E series?\u003c\/p\u003e\n\u003cp\u003eThe UT8805E is the entry of the Performance cohort: 5½-digit precision, 5,000 rdgs\/s maximum reading rate, full SCPI automation over LAN\/RS-232\/USB, four-wire resistance, dual display, math\/statistics, and 10,000-reading internal storage. For higher resolution (6½-digit), faster reading rate (10,000 rdgs\/s), and larger storage (32 Gb NAND Flash), step up to the UT8806E. For GPIB connectivity, see the UT8806EG.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat instrument-control libraries does this multimeter support?\u003c\/p\u003e\n\u003cp\u003eThe UT8805E responds to a SCPI command set compatible with the mainstream multimeter command set, with VXI-11 over LAN and USBTMC over USB-Device. It works with pyvisa, industry-standard VISA implementations, LabVIEW Instrument Control, MATLAB Instrument Control Toolbox, and equivalent controllers. RS-232 is also available for established automated-test scripts or embedded controllers without an Ethernet path.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the UT8805E factory-calibrated, and how often does it need recalibration?\u003c\/p\u003e\n\u003cp\u003eYes — every UT8805E ships with a factory calibration certificate. The recommended recalibration interval is once per year for metrology-traceable measurement applications. For routine workbench use where the meter is being used for relative comparisons or go\/no-go checks against known references, longer intervals are acceptable. Recalibration is performed through Uni-Trend or an accredited third-party calibration laboratory.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat probes and accessories ship with the UT8805E?\u003c\/p\u003e\n\u003cp\u003eThe UT8805E ships with the standard probe and lead set appropriate to its measurement range, a power cord, the USB-Device cable for PC connection, the included software disc or download link, a user manual, and the factory calibration certificate. For four-wire (Kelvin) resistance measurement, dedicated four-wire test leads are recommended for low-resistance accuracy and are available as an accessory. Verify the included contents against the packing list on delivery.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Digits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5½ (5.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e199,999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic DC Voltage Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.015%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Voltage Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Current Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1nA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance Measurement Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Reading Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000 rdgs\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrue-RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-Ranging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance Range (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Hz – 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Frequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-270°C to 1820°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFour-Wire Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDual Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMath Operations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatistics, Limits, Pass\/Fail, dB, dBm, Relative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3in TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480×272\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLAN \/ RS-232 \/ USB-Host \/ USB-Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Command Set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI (VXI-11, USBTMC, IEEE-488.2-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=27\"\u003eUT8805E Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n  \u003cli\u003eUT8800 series safety instructions attachment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":48660722417803,"sku":"180908080072X","price":489.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/5387\/6875\/files\/UT8805E_Probes.jpg?v=1785212009"},{"product_id":"ute323-3-ch-high-precision-digital-power-meter","title":"UTE323 3-Ch High-Precision Digital Power Meter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTE323 Series\u003c\/strong\u003e is a three-channel high-precision digital power meter for three-phase and multi-rail power measurement. Three synchronized measurement channels capture a full three-phase system — or three independent DC\/AC rails — in one instrument, with per-channel and total power, power factor, frequency, energy and harmonics.\u003c\/p\u003e\n\u003cp\u003eIt samples at 300 kSa\/s across a DC to 300 kHz bandwidth and supports every standard wiring configuration (1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A). The UTE323 communicates over RS-232; the UTE323G substitutes GPIB for instrument-bus racks. Measurement firmware and accuracy are identical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — UTE323 Series\u003c\/h2\u003e\n\u003cp\u003eTwo models, one platform. They differ only by communication interface — channel count, accuracy, 300 kSa\/s sampling, wiring modes and harmonic analysis are identical:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:20%\"\u003e\n\u003ccol style=\"width:14%\"\u003e\n\u003ccol style=\"width:40%\"\u003e\n\u003ccol style=\"width:26%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eChannels\u003c\/th\u003e\n\u003cth\u003eWiring Modes\u003c\/th\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE323\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE323G\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ \u003cstrong\u003eGPIB\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eChoose by the interface your test bench uses.\u003c\/p\u003e\n\u003cp\u003eNeed single-phase high-voltage measurement, or a compact panel meter? See the single-channel UTE310 Series (600 V \/ 1000 V single-phase) or the UTE9800+ Series compact power meters — distinct instrument lines for different measurement needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"product-key-features\"\u003e\n\u003cli\u003eThree synchronized measurement channels — full three-phase or three independent rails\u003c\/li\u003e\n\u003cli\u003eWiring modes: 1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/li\u003e\n\u003cli\u003e300 kSa\/s synchronous sampling on all channels\u003c\/li\u003e\n\u003cli\u003eDC to 300 kHz measurement bandwidth\u003c\/li\u003e\n\u003cli\u003ePer-channel and total power, PF, frequency and energy\u003c\/li\u003e\n\u003cli\u003eHarmonic analysis to the 50th order, per channel\u003c\/li\u003e\n\u003cli\u003eEnergy integration (Wh \/ Ah) per channel\u003c\/li\u003e\n\u003cli\u003e5-inch TFT-LCD with simultaneous waveform display\u003c\/li\u003e\n\u003cli\u003eD\/A analog output for external recording\u003c\/li\u003e\n\u003cli\u003eRS-232 standard; GPIB on UTE323G in its place\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTE323 Series Details\u003c\/h2\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Display_sq.jpg?v=1770232639\" alt=\"UTE323 multi-parameter measurement display\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eUTE323 multi-parameter measurement display\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eThree-Phase \u0026amp; Multi-Rail Wiring Modes\u003c\/h3\u003e\n\u003cp\u003eThe UTE323 supports every standard configuration — single-phase two\/three-wire, three-phase three\/four-wire and the 3V3A method. One instrument measures a complete three-phase inverter output, a three-rail DC bus or three independent converters without re-cabling between standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Display_sq.jpg?v=1770232639\" alt=\"UTE323 multi-parameter measurement display\"\u003e\u003cspan class=\"lightbox-caption\"\u003eUTE323 multi-parameter measurement display\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSynchronous 300 kSa\/s Multi-Channel Sampling\u003c\/h3\u003e\n\u003cp\u003eAll three channels sample synchronously at 300 kSa\/s, so phase relationships and per-phase power are measured against a common time base — essential for true three-phase power and imbalance measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Sample_rate_sq.jpg?v=1770232639\" alt=\"300 kSa\/s synchronous sampling on all channels\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003e300 kSa\/s synchronous sampling on all channels\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Sample_rate_sq.jpg?v=1770232639\" alt=\"300 kSa\/s synchronous sampling on all channels\"\u003e\u003cspan class=\"lightbox-caption\"\u003e300 kSa\/s synchronous sampling on all channels\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_wide_bandwidth_sq.jpg?v=1770232639\" alt=\"DC to 300 kHz wide-bandwidth measurement\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eDC to 300 kHz wide-bandwidth measurement\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eDC to 300 kHz Wide-Bandwidth Measurement\u003c\/h3\u003e\n\u003cp\u003eThe wide DC–300 kHz bandwidth keeps switching content and harmonics in the per-phase power calculation, so three-phase inverter and drive measurements reflect the real waveform rather than the fundamental alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_wide_bandwidth_sq.jpg?v=1770232639\" alt=\"DC to 300 kHz wide-bandwidth measurement\"\u003e\u003cspan class=\"lightbox-caption\"\u003eDC to 300 kHz wide-bandwidth measurement\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003ePer-Channel Harmonic Analysis\u003c\/h3\u003e\n\u003cp\u003eHarmonic analysis to the 50th order runs on each channel independently, quantifying per-phase distortion on three-phase rectifier and drive front ends.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_harmonics_sq.jpg?v=1770232639\" alt=\"Harmonic analysis to the 50th order, per channel\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eHarmonic analysis to the 50th order, per channel\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_harmonics_sq.jpg?v=1770232639\" alt=\"Harmonic analysis to the 50th order, per channel\"\u003e\u003cspan class=\"lightbox-caption\"\u003eHarmonic analysis to the 50th order, per channel\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_integral_sq.jpg?v=1770232639\" alt=\"Energy integration (Wh \/ Ah) per channel\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eEnergy integration (Wh \/ Ah) per channel\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003ePer-Channel Energy Integration\u003c\/h3\u003e\n\u003cp\u003eWatt-hour and amp-hour integration accumulate per channel for three-phase efficiency runs and long-duration multi-rail energy profiling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_integral_sq.jpg?v=1770232639\" alt=\"Energy integration (Wh \/ Ah) per channel\"\u003e\u003cspan class=\"lightbox-caption\"\u003eEnergy integration (Wh \/ Ah) per channel\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSimultaneous Waveform Display\u003c\/h3\u003e\n\u003cp\u003eThe 5-inch display shows all channel waveforms together, confirming phase rotation and wiring before the measurement is trusted.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_display_wave_sq.jpg?v=1770232639\" alt=\"Simultaneous waveform display across channels\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eSimultaneous waveform display across channels\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_display_wave_sq.jpg?v=1770232639\" alt=\"Simultaneous waveform display across channels\"\u003e\u003cspan class=\"lightbox-caption\"\u003eSimultaneous waveform display across channels\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_da_sq.jpg?v=1770232639\" alt=\"D\/A analog output for external recording\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eD\/A analog output for external recording\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eD\/A Output\u003c\/h3\u003e\n\u003cp\u003eA D\/A analog output drives a chart recorder or DAQ for long-term trend logging of any measured channel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_da_sq.jpg?v=1770232639\" alt=\"D\/A analog output for external recording\"\u003e\u003cspan class=\"lightbox-caption\"\u003eD\/A analog output for external recording\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eGPIB in Place of RS-232 — UTE323G\u003c\/h3\u003e\n\u003cp\u003eThe UTE323G substitutes a GPIB (IEEE-488) port for RS-232 — it does not add GPIB alongside it. USB and LAN are present on both models, so if you automate over LAN the base UTE323 already covers you; the UTE323G is for racks built on a GPIB instrument bus.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eThree-Phase Inverter \u0026amp; Motor-Drive Efficiency\u003c\/h3\u003e\n\u003cp\u003eMeasure three-phase output power and per-phase imbalance on inverter and motor-drive designs in a single instrument, with synchronous sampling that holds phase relationships true.\u003c\/p\u003e\n\u003ch3\u003eMulti-Rail \u0026amp; Multi-Converter Test\u003c\/h3\u003e\n\u003cp\u003eThree independent channels measure three DC\/AC rails or three converters at once — one instrument instead of three single-channel meters on a multi-output power-electronics bench.\u003c\/p\u003e\n\u003ch3\u003eProduction \u0026amp; QA Test Bench\u003c\/h3\u003e\n\u003cp\u003ePer-channel limits, energy integration and a single RS-232\/GPIB or LAN connection make the UTE323 a compact end-of-line and QA power-test station for small test labs and consultancies.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003cp\u003eUTE-series test cables support safe three-phase connection. Pair the UTE323 with UNI-T programmable sources and electronic loads for a complete three-phase power-characterization bench.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eCan the UTE323 measure a full three-phase system at once?\u003c\/h3\u003e\n\u003cp\u003eYes. Three synchronized channels and the 3P3W \/ 3P4W \/ 3V3A wiring modes measure a complete three-phase system in one instrument.\u003c\/p\u003e\n\u003ch3\u003eCan the three channels measure independent rails instead of one three-phase system?\u003c\/h3\u003e\n\u003cp\u003eYes. The three channels can measure three independent DC\/AC rails or converters simultaneously.\u003c\/p\u003e\n\u003ch3\u003eDoes the UTE323G add GPIB on top of RS-232?\u003c\/h3\u003e\n\u003cp\u003eNo — it substitutes GPIB for RS-232. USB and LAN are on both models; the UTE323G is for GPIB-bus racks.\u003c\/p\u003e\n\u003ch3\u003eDoes each channel measure harmonics?\u003c\/h3\u003e\n\u003cp\u003eYes — per-channel harmonic analysis to the 50th order.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTE323 \/ UTE323G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (synchronous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75mV – 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5mA – 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5W – 12kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300kSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC, 0.1Hz – 300kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1st – 50th\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-inch TFT-LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface (UTE323)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface (UTE323G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ GPIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=116\"\u003eUTE323 Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUT-L0110-BB x3\u003c\/li\u003e\n  \u003cli\u003eUT-L0110-BU x3\u003c\/li\u003e\n  \u003cli\u003eRed\/Black termals x6\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":48660723957899,"sku":"182700300017X","price":3144.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/5387\/6875\/files\/UTE323_1_sq.jpg?v=1785212040"},{"product_id":"uti740h-400-professional-enhanced-thermal-imager","title":"UTi740H+ 400 Professional Enhanced Thermal Imager","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UNI-T UTi740H+ is a manual-focus handheld thermal camera built for industrial and building professionals who need both resolution and reach. A 400×300 infrared detector pairs with a \u0026lt;35mK thermal sensitivity rating to resolve fine temperature differences, and Super Resolution lifts captured images to 800×600 for sharper detail in reports. The 4.3″ capacitive touchscreen (800×480) makes menu navigation and on-screen measurement quick in the field.\u003c\/p\u003e\n\u003cp\u003eA manual focus ring lets the UTi740H+ sharpen on both near and distant targets — the difference between a usable measurement and a blurred frame when shooting a panel across a room or a connector at the top of a pole. Measurements save as radiometric photos or video, and Wi-Fi connectivity streams live or transfers files to the PC and mobile analysis software. IP54 sealing and a 2-meter drop rating handle job-site conditions, and the detachable 5200 mAh battery swaps in seconds.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e400×300 infrared resolution\u003c\/strong\u003e — high-definition thermal detail, lifted to 800×600 with Super Resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u0026lt;35mK thermal sensitivity (NETD)\u003c\/strong\u003e — resolves fine temperature differences for early fault detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual focus ring\u003c\/strong\u003e — sharp measurement of both near and distant targets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4.3″ capacitive touchscreen (800×480)\u003c\/strong\u003e — fast menu navigation and on-screen measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e≤30 Hz frame rate\u003c\/strong\u003e — smooth live imaging while panning across equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiometric video recording\u003c\/strong\u003e — capture MP4 and UIR video with full temperature data\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-point analyzer toolkit\u003c\/strong\u003e — 16 points, lines, rectangles, and circles with Hi\/Lo tracking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eT-Mix fusion\u003c\/strong\u003e — blends thermal and visible images to locate faults in context\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWi-Fi live streaming\u003c\/strong\u003e — stream to PC\/app or transfer radiometric files wirelessly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetachable 5200 mAh battery\u003c\/strong\u003e — field-replaceable, approx. 4h per charge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP54 + 2m drop rating\u003c\/strong\u003e — sealed and ruggedized for the job site\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eUNI-T UTi740H+ Details\u003c\/h2\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTi760H_app_2.jpg\" alt=\"Thermal image of mechanical equipment with multi-point temperature measurement\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eManual focus sharpens both near and distant targets\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eManual Focus Ring for Distance Inspections\u003c\/h3\u003e\n\u003cp\u003eThe UTi740H+'s manual focus ring is the feature that separates it from point-and-shoot thermal cameras. Bringing a distant target into sharp focus — a busbar across a substation yard, a connector at the top of a pole, a roof-mounted unit from ground level — is what makes the measurement trustworthy. A defocused thermal image does not just look soft; it averages temperature across pixels and understates a real hotspot.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eT-Mix Fusion Overlay\u003c\/h3\u003e\n\u003cp\u003eT-Mix fusion blends the thermal image with the 5 MP visible-light camera so a hotspot is shown in the context of the equipment around it. Instead of a floating orange blob, the operator sees which specific terminal, bearing, or pipe is running hot — which makes the captured image far more useful in a report handed to someone who was not on site.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eFull Analyzer Toolkit + Isotherm + Hi\/Lo Tracking\u003c\/h3\u003e\n\u003cp\u003eOn-screen measurement covers 16 points, 16 lines, 16 rectangles, and 16 circles simultaneously — enough to document an entire panel of terminals in one frame. Hi\/Lo temperature tracking automatically marks the hottest and coldest pixels in the scene, and the Hi\/Lo alarm flags any reading past a preset threshold with an on-screen animation and buzzer. Five isotherm modes (Auto, Manual, Above, Below, Section) paint a chosen temperature band in contrasting color.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTi760H_app_14.jpg\" alt=\"Thermal image of a switchgear contactor block with on-screen analyzer measuring terminal temperatures\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eOn-screen analyzer measuring switchgear terminal temperatures\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eHigh-Resolution IPS Touch Display\u003c\/h3\u003e\n\u003cp\u003eThe 4.3-inch capacitive touchscreen runs at 800×480, so menus, measurement tools, and the live image are all driven by tap and swipe rather than button-stepping. For a technician working in gloves on a ladder, direct touch on a large bright panel is faster than navigating a keypad.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eRadiometric Video and Wi-Fi Live Streaming\u003c\/h3\u003e\n\u003cp\u003eThe UTi740H+ records radiometric video in MP4 and UIR formats — the UIR file keeps full per-pixel temperature data, so a recorded heating or cooling event can be analyzed frame by frame afterward. Wi-Fi live streaming sends the view to a phone, tablet, or PC in real time, useful for showing a second person the scene or recording a walk-through to the analysis software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eDetachable Battery and Field Ruggedness\u003c\/h3\u003e\n\u003cp\u003eThe 5200 mAh lithium-ion pack is detachable and charges over USB Type-C, giving approximately 4 hours of continuous runtime with Wi-Fi off; a spare pack extends that to a full shift. An IP54 rating protects against dust and splashing water, and the 2-meter drop spec covers the falls that happen on real job sites.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — UTi740H+ vs. the H+ \/ 760H Enhanced Series\u003c\/h2\u003e\n\u003cp\u003eThe UTi740H+ and UTi760H share the same chassis, \u0026lt;35mK sensitivity, manual-focus optics, 4.3″ touchscreen, 16-point analyzer, radiometric video, and 30 Hz frame rate. They differ in one thing that matters most: detector resolution. More pixels mean finer thermal detail and the ability to measure smaller targets at a given distance. The matrix below shows the difference.\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:34%\"\u003e\n\u003ccol style=\"width:33%\"\u003e\n\u003ccol style=\"width:33%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eUTi740H+\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003eUTi760H\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInfrared resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400×300\u003c\/td\u003e\n\u003ctd\u003e640×480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuper resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800×600\u003c\/td\u003e\n\u003ctd\u003e1280×960\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTi760H_app_14.jpg\" alt=\"Thermal image of a switchgear contactor block with on-screen analyzer measuring terminal temperatures\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eSwitchgear and contactor terminal inspection\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eElectrical Distribution and Switchgear\u003c\/h3\u003e\n\u003cp\u003eLoose or corroded connections, overloaded phases, and failing contactors all radiate heat before they fault. Scanning switchgear and distribution equipment locates the warm terminal without contact, and the 16-point analyzer documents the whole assembly in one frame for the work order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eOverhead Lines and Utility Distribution\u003c\/h3\u003e\n\u003cp\u003eManual focus and high resolution let the camera measure overhead conductors, insulators, and tower hardware from the ground. Overheating clamps and degraded insulators show up clearly against the cool sky, so utility crews can prioritize repairs without a bucket truck on every span.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTi760H_app_8.jpg\" alt=\"Thermal image of overhead transmission tower and power line conductors\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eOverhead transmission tower and conductor inspection\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTi760H_app_11.jpg\" alt=\"Thermal image of overhead line conductor splices and connectors\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eOverhead line splice and connector hotspot inspection\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eConnector and Splice Hotspots\u003c\/h3\u003e\n\u003cp\u003eSplices and connectors are the usual failure points on a distribution line. A high-resolution thermal frame separates a warm splice from the conductor running into it, identifying the specific joint that needs service rather than flagging the whole span.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eMotors, Pumps, and Mechanical Equipment\u003c\/h3\u003e\n\u003cp\u003eBearing wear, misalignment, cooling faults, and process-pipe issues all change surface temperature. Routine thermal checks of motors, pumps, compressors, and pipework catch those signatures early, turning unplanned breakdowns into scheduled maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTi760H_app_5.jpg\" alt=\"Thermal image of a compressor and pipework showing surface hotspots with on-screen temperature markers\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eMechanical equipment and pipework thermal inspection\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and In the Box\u003c\/h2\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUTi740H+ thermal camera\u003c\/li\u003e\n\u003cli\u003eDetachable 5200 mAh Li-ion battery pack (UT-M17)\u003c\/li\u003e\n\u003cli\u003eUSB Type-C cable\u003c\/li\u003e\n\u003cli\u003e32GB SD card\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpare UT-M17 Li-ion Battery Pack for all-day operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the difference between the UTi740H+ and the UTi760H?\u003c\/h3\u003e\n\u003cp\u003eDetector resolution. The UTi740H+ is 400×300 and the UTi760H is 640×480; both share the same sensitivity, optics design, touchscreen, analyzer, and video features. Higher resolution resolves smaller targets at a given distance. See the UTi760H for the other resolution option.\u003c\/p\u003e\n\u003ch3\u003eDoes it record video?\u003c\/h3\u003e\n\u003cp\u003eYes. It records radiometric video in MP4 and UIR formats; the UIR file preserves full per-pixel temperature data for frame-by-frame analysis afterward.\u003c\/p\u003e\n\u003ch3\u003eWhat is Super Resolution?\u003c\/h3\u003e\n\u003cp\u003eSuper Resolution enhances the captured image to 800×600 pixels for sharper detail in saved images and reports, beyond the native detector resolution.\u003c\/p\u003e\n\u003ch3\u003eCan I focus on distant targets?\u003c\/h3\u003e\n\u003cp\u003eYes. The manual focus ring sharpens both near and distant targets, which is essential for accurate measurement of equipment across a room or overhead.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-lightboxes\"\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTi760H_app_2.jpg\" alt=\"Thermal image of mechanical equipment with multi-point temperature measurement\"\u003e\u003cspan class=\"lightbox-caption\"\u003eThermal image of mechanical equipment with multi-point temperature measurement\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTi760H_app_14.jpg\" alt=\"Thermal image of a switchgear contactor block with on-screen analyzer measuring terminal temperatures\"\u003e\u003cspan class=\"lightbox-caption\"\u003eThermal image of a switchgear contactor block with on-screen analyzer measuring terminal temperatures\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTi760H_app_14.jpg\" alt=\"Thermal image of a switchgear contactor block with on-screen analyzer measuring terminal temperatures\"\u003e\u003cspan class=\"lightbox-caption\"\u003eThermal image of a switchgear contactor block with on-screen analyzer measuring terminal temperatures\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTi760H_app_8.jpg\" alt=\"Thermal image of overhead transmission tower and power line conductors\"\u003e\u003cspan class=\"lightbox-caption\"\u003eThermal image of overhead transmission tower and power line conductors\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTi760H_app_11.jpg\" alt=\"Thermal image of overhead line conductor splices and connectors\"\u003e\u003cspan class=\"lightbox-caption\"\u003eThermal image of overhead line conductor splices and connectors\u003c\/span\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTi760H_app_5.jpg\" alt=\"Thermal image of a compressor and pipework showing surface hotspots with on-screen temperature markers\"\u003e\u003cspan class=\"lightbox-caption\"\u003eThermal image of a compressor and pipework showing surface hotspots with on-screen temperature markers\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIR Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400×300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNETD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 35mK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C (-4 °F) to 650 °C (1202 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.5 °C or ±1.5% (whichever greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29° × 21.5°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 - 14µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePixel Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefresh Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpatial Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.26mrad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFocus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual Focus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Zoom\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x - 6x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuper Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Blending\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsotherm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal, Visual image, T-Mix fusion, PIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRadiometric JPEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMP4 \u0026amp; UIR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn Screen Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Points\/16 Lines\/16 Rectangles\/16 Circles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Camera\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5MP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiFi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Type-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in 32GB \u0026amp; 32GB SD card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800×480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnglish, French, German, Italian, Spanish, Swedish, Polish, Czech\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5200 mAh detachable Li-ion battery pack (UT-M17)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 4h (with Wi-Fi off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 × 130 × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/thermal.uni-trend.com\/product\/uti740h-2\/#Downloads5fb0-a510\"\u003eUTi740H+ Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/thermal.uni-trend.com\/product\/uti740h-2\/#Downloads5fb0-a510\"\u003eUTi740H+ User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":48660724547723,"sku":"180700100354X","price":1899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/5387\/6875\/files\/UTi740H_-1_sq_2747f345-6ed3-4f37-b959-c9943e4e51e3.jpg?v=1785212052"},{"product_id":"uts5000a-pnm-phase-noise-measurement-option","title":"UTS5000A-PNM Phase Noise Measurement Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UTS5000A-PNM adds dedicated phase noise measurement for oscillators, synthesizers, and clock sources — phase noise vs. offset frequency with high sensitivity. The option is enabled by a software license keyed to the spectrum analyzer's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Noise vs. Offset\u003c\/strong\u003e — Single-sideband phase noise from Hz to MHz offsets in one sweep.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Carrier Detection\u003c\/strong\u003e — Automatically identifies the carrier frequency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Phase Noise\u003c\/strong\u003e — Calculates jitter over a specified offset range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpur Identification\u003c\/strong\u003e — Identifies discrete spurious signals in the phase noise spectrum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOscillator Characterization\u003c\/strong\u003e — Measure TCXO\/OCXO phase noise for PLL and data converter requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynthesizer Validation\u003c\/strong\u003e — Verify synthesizer phase noise profile at critical offsets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with all UTS5000A Series spectrum analyzers. The same capability is offered on other UNI-T spectrum analyzer families: UTS3000A, UTS7000A.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the spectrum analyzer's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the spectrum analyzer from a USB drive through the option-install menu. Refer to the spectrum analyzer's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":48660725301387,"sku":"191501700003","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/5387\/6875\/files\/UTS5000A-PNM.png?v=1785212067"},{"product_id":"utg9504t-500-mhz-4ch-elite-series-arbitrary-waveform-generator","title":"UTG9504T+ 500 MHz 4Ch Elite-Series Arbitrary Waveform Generator","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTG9504T+\u003c\/strong\u003e is a four-channel arbitrary waveform generator with a maximum sine output of 500 MHz, built around a 16-bit DAC and a 2.5 GSa\/s sample rate (2× interpolation). All four channels deliver equal performance with full 20 Vpp output (high-Z), and an 8 pts to 128 Mpts per-channel arbitrary memory supports long-form custom stimulus. A 10.1-inch capacitive touch display replaces menu-driven navigation with direct parameter manipulation.\u003c\/p\u003e\n\u003cp\u003e170 MHz square and 120 MHz pulse output, 1 µHz frequency resolution across the full 500 MHz range, harmonic distortion below 0.07% (DC to 20 kHz), and an 800 MHz hardware frequency counter. Fifteen analog and digital modulation types — including 3FSK, 4FSK, QAM, and the full BPSK \/ QPSK \/ OSK set. Linear, logarithmic, list, and step sweep. Three burst modes. Advanced Multi-Pulse, Multi-Tone, Sequence, Pattern, I\/Q, and Expression functions. Over 200 built-in arbitrary waveforms with SPI \/ I²C \/ UART digital-protocol output.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 MHz sine \/ 170 MHz square \/ 120 MHz pulse\u003c\/strong\u003e — four-channel output with 1 µHz frequency resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour equal-performance channels, 20 Vpp\u003c\/strong\u003e — every channel delivers the full output envelope; independent or combined operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 GSa\/s sample rate, 16-bit DAC\u003c\/strong\u003e — with 2× interpolation; 8 pts to 128 Mpts per-channel arbitrary memory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic distortion below 0.07%\u003c\/strong\u003e — low distortion with −80 dBc spurious-free dynamic range and high SNR on large DC offsets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15 modulation types\u003c\/strong\u003e — AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, PWM — analog and digital in one instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced functions\u003c\/strong\u003e — Multi-Pulse, Multi-Tone, Sequence, Pattern, I\/Q, and Expression-based waveform generation built in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide-dynamic pulse, fast edges\u003c\/strong\u003e — 100 ps edge-time adjustment, 3 ns minimum pulse width, per-pulse edge control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRBS PN3 to PN33\u003c\/strong\u003e — 1 µbps to 300 Mbps with adjustable edge time for serial-link and jitter-tolerance test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e800 MHz hardware frequency counter\u003c\/strong\u003e — 100 mHz to 800 MHz, 8-digit, AC \/ DC \/ HF-reject coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver 200 built-in arbitrary waveforms\u003c\/strong\u003e — plus SPI, I²C, and UART digital-protocol output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-inch capacitive touch display\u003c\/strong\u003e — 1280 × 800; direct parameter manipulation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTG9504T+ Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eFour Equal-Performance Channels, 20 Vpp\u003c\/h3\u003e\n\u003cp\u003eFour independent channels in the standard configuration, every one delivering identical performance — there is no derated second bank. Each channel produces the full output envelope to 20 Vpp (high-Z) and can run fully independently, so clock, data, trigger, and stimulus can all originate from one instrument at full specification on every channel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_four-channel_output.png\" alt=\"UTG9504T+ four equal-performance channels, 20 vpp\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFour equivalent-performance channels with full 20 Vpp output on every channel.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_channel_coupling_merge.png\" alt=\"UTG9504T+ channel coupling and merging\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFrequency, amplitude, and phase coupling across channels; outputs merge into composite signals.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eChannel Coupling and Merging\u003c\/h3\u003e\n\u003cp\u003eChannels can be freely coupled with configurable frequency, amplitude, and phase relationships (coupling ratio 0.0001 to 10,000), so a parameter change on one channel propagates to its coupled partners by a defined ratio and offset. Outputs can also be merged into arbitrary combinations — for example CH1 = CH1 + CH2 + CH3 + CH4 — producing summed and composite signals from a single instrument without external combiners.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eLow-Distortion Output and High SNR\u003c\/h3\u003e\n\u003cp\u003eDigital sampling produces sine, square, ramp, pulse, arbitrary, harmonic, noise, DC, and PRBS waveforms with low distortion and low jitter. Total harmonic distortion stays below 0.07% from DC to 20 kHz, with a spurious-free dynamic range to −80 dBc. A small signal superimposed on a large DC offset retains a high signal-to-noise ratio — useful when the stimulus must be quieter than the device under test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_low_distortion_output.png\" alt=\"UTG9504T+ low-distortion output and high snr\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eTHD below 0.07% (DC to 20 kHz) with −80 dBc spurious-free dynamic range.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_pulse_wave.png\" alt=\"UTG9504T+ wide-dynamic pulse with fast, independently adjustable edges\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eEdge time adjustable in 100 ps steps; 3 ns minimum pulse width; per-pulse edge control.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eWide-Dynamic Pulse with Fast, Independently Adjustable Edges\u003c\/h3\u003e\n\u003cp\u003eThe pulse generator offers high-precision adjustable edge times with increments as fine as 100 ps and a minimum pulse width of 3 ns (Typ.), generating high harmonic content comparable to a dedicated pulse generator. Edge time can be set independently for each pulse, down to a 2 ns minimum, and pulse jitter stays at 200 ps across the operating range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e15 Modulation Types in One Instrument\u003c\/h3\u003e\n\u003cp\u003eFifteen analog and digital modulation schemes are built in: AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, and PWM. Each channel supports independent or simultaneous internal\/external modulation and internal\/external\/manual triggering, alongside Linear\/Logarithmic\/List\/Step frequency sweep and N-cycle\/gate\/pulse-train burst.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_modulation_types.png\" alt=\"UTG9504T+ 15 modulation types in one instrument\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFifteen modulation types covering analog and digital schemes, plus sweep and burst.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_multi_pulse.png\" alt=\"UTG9504T+ multi-pulse and multi-tone generation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMulti-Pulse: 2–30 pulses with per-pulse edge control. Multi-Tone: 2–8 components.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eMulti-Pulse and Multi-Tone Generation\u003c\/h3\u003e\n\u003cp\u003eMulti-Pulse produces pulse trains of 2 to 30 pulses with independently adjustable edge times and high\/gap times for rapid, precise multi-pulse testing without custom code. Multi-Tone synthesizes 2 to 8 simultaneous frequency components, reproducing real-world multi-frequency signals for nonlinear-distortion analysis, wideband frequency-response work, and communication-system verification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSequence, Pattern, I\/Q, and Expression Functions\u003c\/h3\u003e\n\u003cp\u003eSequence chains up to 1,024 waveforms totalling 128 Mpts per channel with internal, external, manual, and timer start events for one-time loading of multiple test cases. Pattern outputs customizable code (NRZ\/RZ\/Manchester) at TTL, CMOS, ECL, and PECL logic standards. I\/Q generation delivers baseband output at any symbol rate to 1.25 GSa\/s. Expression builds complex waveforms directly from mathematical formulas.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_sequence_dynamic_testing_c274c9bd-1488-4a0c-9e5e-ead5a55261fe.png\" alt=\"UTG9504T+ sequence, pattern, i\/q, and expression functions\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eSequence, Pattern, I\/Q, and Expression — advanced waveform generation built in.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_edit_arb_1.png\" alt=\"UTG9504T+ built-in arbitrary editor, digital bus, and 800 mhz counter\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in arbitrary editor with PC-side editing; SPI\/I²C\/UART output; 800 MHz counter.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eBuilt-In Arbitrary Editor, Digital Bus, and 800 MHz Counter\u003c\/h3\u003e\n\u003cp\u003eThe integrated arbitrary-waveform editor supports manual drawing, line drawing, and expression-based generation, and also runs on a PC over USB or LAN. Point-by-point output spans 8 pts to 128 Mpts with 16-bit vertical resolution. SPI, I²C, and UART digital-protocol output is built in, and a high-precision hardware frequency counter measures 100 mHz to 800 MHz with 8-digit resolution and selectable AC \/ DC \/ HF-reject coupling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe UTG9504T+ envelope — four equal-performance channels, 2.5 GSa\/s, 128 Mpts per channel, THD \u0026lt; 0.07%, 15-type modulation, the full advanced-function set, and a capacitive touch UI — targets benchtop work that needs genuine multi-channel stimulus, deep arbitrary support, or wide modulation coverage.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-channel embedded development\u003c\/strong\u003e — four matched channels drive clock, data, trigger, and stimulus simultaneously from one instrument, conserving bench space while keeping every channel at full performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRF and communications stimulus\u003c\/strong\u003e — 3FSK, 4FSK, BPSK, QPSK, OSK, QAM digital modulation and SUM \/ DSB-AM analog modulation drive component characterization and protocol development across the full output range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-speed digital and serial-link test\u003c\/strong\u003e — fast adjustable edges with 100 ps steps, PRBS PN3 to PN33, and SPI \/ I²C \/ UART protocol output for interface and jitter-tolerance work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudio and instrumentation testing\u003c\/strong\u003e — THD below 0.07% from DC to 20 kHz when characterizing op-amp distortion, ADC noise floors, and audio-band response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-form arbitrary playback\u003c\/strong\u003e — up to 128 Mpts per channel holds extended protocol streams, sensor-emulation traces, and complex composite waveforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/Q and modulated-carrier work\u003c\/strong\u003e — baseband I\/Q at any symbol rate to 1.25 GSa\/s for communication-system verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated test (ATE)\u003c\/strong\u003e — LAN\/USB remote control and instrument-manager software for synchronized multi-instrument benches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord conforming to destination country standard\u003c\/li\u003e\n\u003cli\u003eUSB data cable (UT-D14)\u003c\/li\u003e\n\u003cli\u003eBNC-to-BNC cable × 4 (UT-L45)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat does “2.5 GSa\/s with 2× interpolation” mean in practice?\u003c\/p\u003e\n\u003cp\u003eThe DAC runs at a native rate, and a digital interpolation filter inserts estimated samples to produce a 2.5 GSa\/s effective output stream. The reconstruction filter then sees a higher-rate stream and passes more high-frequency signal content with less alias distortion, giving finer detail in the upper portion of the output range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDo all four channels run at full performance simultaneously?\u003c\/p\u003e\n\u003cp\u003eYes. The four channels are equal-performance — each delivers the full output envelope to 20 Vpp (high-Z) independently, with no derating when multiple channels are active. Channels can also be coupled by frequency \/ amplitude \/ phase ratio or merged into composite outputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat modulation, sweep, and burst envelope does the UTG9504T+ cover?\u003c\/p\u003e\n\u003cp\u003eModulation: 15 types — AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, PWM. Sweep: Linear, Logarithmic, List, Step with internal \/ external \/ manual triggers. Burst: N-cycle (1 to 1,000,000 cycles), gate, and pulse-train.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat advanced waveform functions are included?\u003c\/p\u003e\n\u003cp\u003eMulti-Pulse (2 to 30 pulses, per-pulse edge \/ high \/ gap times), Multi-Tone (2 to 8 components), Sequence (up to 1,024 waveforms, 128 Mpts per channel), Pattern (NRZ \/ RZ \/ Manchester at TTL, CMOS, ECL, PECL levels), I\/Q (baseband to 1.25 GSa\/s), and Expression (formula-defined waveforms) are all standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat digital-protocol outputs are supported?\u003c\/p\u003e\n\u003cp\u003eSPI, I²C, and UART are built in. SPI and I²C run a 1 Hz to 50 MHz clock with up to 2,048-byte data depth; UART supports custom baud rates from 1 to 1,000,000 with configurable data, stop, and parity bits — useful for driving and emulating embedded serial buses directly from the generator.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_four-channel_output.png\" alt=\"UTG9504T+ four equal-performance channels, 20 vpp\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFour independent equal-performance channels, 20 Vpp on every channel\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_channel_coupling_merge.png\" alt=\"UTG9504T+ channel coupling and merging\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eChannel coupling and merging — ratio-linked parameters and combined outputs\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_low_distortion_output.png\" alt=\"UTG9504T+ low-distortion output and high snr\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLow-distortion continuous-wave output with high SNR on large DC offsets\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_pulse_wave.png\" alt=\"UTG9504T+ wide-dynamic pulse with fast, independently adjustable edges\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eWide-dynamic pulse output with fine, independently adjustable edge times\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_modulation_types.png\" alt=\"UTG9504T+ 15 modulation types in one instrument\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFifteen modulation types — analog and digital — with sweep and burst\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_multi_pulse.png\" alt=\"UTG9504T+ multi-pulse and multi-tone generation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMulti-Pulse and Multi-Tone generation for complex timing and spectral test\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_sequence_dynamic_testing_c274c9bd-1488-4a0c-9e5e-ead5a55261fe.png\" alt=\"UTG9504T+ sequence, pattern, i\/q, and expression functions\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eAdvanced functions: Sequence, Pattern, I\/Q, and Expression-based waveforms\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_edit_arb_1.png\" alt=\"UTG9504T+ built-in arbitrary editor, digital bus, and 800 mhz counter\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in arbitrary editor, digital-bus output, and 100 mHz–800 MHz hardware counter\u003c\/span\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax sine frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax square frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pulse frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4, independent and equal-performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s (2× interpolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-bit (including sign)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArbitrary waveform length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 pts to 128 Mpts\/CH (expandable to 256 Mpts\/CH with PC software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in arbitrary waveforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver 200, non-volatile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArbitrary file storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 GB internal for arbitrary-waveform files (.bsv\/.csv)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard waveforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSine, Square, Ramp, Pulse, Harmonic, Noise, PRBS, DC, Arbitrary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 — AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, PWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFM frequency offset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 μHz to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 μHz to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic distortion (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC to 10 MHz ≤ −65 dBc; 10–100 MHz ≤ −60 dBc; 100–150 MHz ≤ −50 dBc; 150–200 MHz ≤ −40 dBc; 200–400 MHz ≤ −30 dBc; 400–500 MHz ≤ −28 dBc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-tone frequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kHz to 400 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/Q center frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mHz to 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRamp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µHz to 20 MHz, symmetry 0.00% to 100.00%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear, Logarithmic, List, Step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-cycle, Gate, Pulse-train\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-Pulse, Multi-Tone, Sequence, Pattern, I\/Q, Expression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital-protocol output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSPI, I²C, UART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mHz to 800 MHz hardware frequency counter, AC \/ DC \/ HF-reject coupling, 8-digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput amplitude (50 Ω)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mVpp to 10 Vpp (50 Ω, ≤ 40 MHz band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput amplitude (high-Z)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mVpp to 20 Vpp (high-Z, ≤ 40 MHz band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal harmonic distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.07% (0 dBm, DC to 20 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpurious-free dynamic range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−80 dBc spurious-free dynamic range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ −130 dBc\/Hz @ 10 kHz offset (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse jitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 ps (1 Vpp, 50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArbitrary jitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSquare rise\/fall time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 ns (Typ., square)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum pulse width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 ns (Typ.); edge step to 100 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePRBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePN3 to PN33, 1 µbps to 300 Mbps; edge 2 ns to 1 ks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude flatness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 10 MHz ±0.1 dB; ≤ 60 MHz ±0.2 dB; ≤ 80 MHz ±0.4 dB; ≤ 500 MHz ±0.8 dB (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MHz, ±0.5 ppm initial accuracy (25°C); ±1 ppm aging (first year)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch capacitive touch, 1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host, USB Device, LAN; 10 MHz reference in\/out; external trigger in\/out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protection; overload auto-disables waveform output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VACrms (±10%), 50\/60 Hz; \u0026lt; 50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+10°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 90% RH below +35°C; ≤ 60% RH +35°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e361 mm × 209 mm × 106 mm (W × H × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus; EN 61010-1, EN 61326-1 EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=124\"\u003eUTG9504T+ Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":48660725661835,"sku":"181300100152X","price":6999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/5387\/6875\/files\/UTG9504T__1_sq.jpg?v=1785212076"},{"product_id":"udp5040-40-400w-40v-40a-programmable-dc-switching-power-supply","title":"UDP5040-40 400W 40V\/40A Programmable DC Switching Power Supply","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UDP5040-40\u003c\/strong\u003e is a single-channel 400W programmable DC switching power supply delivering 0–40V and 0–40A with auto-ranging across the rated power envelope. It pairs a wide output range with the regulation accuracy, source-emulation and remote control expected of a professional programmable supply.\u003c\/p\u003e\n\u003cp\u003eVoltage accuracy is ±(0.05% of set + 0.05% of rated) and current accuracy ±(0.5% of set + 0.1% of rated); ripple is held to 50mV p-p with a 100 ppm\/°C temperature coefficient. A 2.4-inch TFT-LCD shows voltage, current and power together, and full SCPI control over USB and LAN drops the UDP5040-40 straight into LabVIEW, Python-VISA or any ATE framework.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — UDP5000 Series\u003c\/h2\u003e\n\u003cp\u003eThe UDP5000 name spans 20 models built on one platform: five voltage classes (40 V \/ 80 V \/ 160 V \/ 250 V \/ 800 V) across four power classes (400 W \/ 800 W \/ 1200 W \/ 2000 W). They differ only in output range and chassis size — control, accuracy, protection and interface are otherwise identical. Compare the full series before selecting:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:14%\"\u003e\n\u003ccol style=\"width:17%\"\u003e\n\u003ccol style=\"width:17%\"\u003e\n\u003ccol style=\"width:17%\"\u003e\n\u003ccol style=\"width:17%\"\u003e\n\u003ccol style=\"width:18%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eRated Power\u003c\/th\u003e\n\u003cth\u003e40 V\u003c\/th\u003e\n\u003cth\u003e80 V\u003c\/th\u003e\n\u003cth\u003e160 V\u003c\/th\u003e\n\u003cth\u003e250 V\u003c\/th\u003e\n\u003cth\u003e800 V\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e400W\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUDP5040-40\u003c\/strong\u003e\u003cbr\u003e0–40A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5080-20\u003cbr\u003e0–20A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5160-8\u003cbr\u003e0–8A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5250-6\u003cbr\u003e0–6A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5800-2\u003cbr\u003e0–2A\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e800W\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\nUDP5040-80\u003cbr\u003e0–80A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5080-40\u003cbr\u003e0–40A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5160-16\u003cbr\u003e0–16A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5250-12\u003cbr\u003e0–12A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5800-4\u003cbr\u003e0–4A\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1200W\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\nUDP5040-120\u003cbr\u003e0–120A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5080-60\u003cbr\u003e0–60A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5160-24\u003cbr\u003e0–24A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5250-18\u003cbr\u003e0–18A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5800-6\u003cbr\u003e0–6A\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2000W\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\nUDP5040-200\u003cbr\u003e0–200A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5080-100\u003cbr\u003e0–100A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5160-40\u003cbr\u003e0–40A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5250-30\u003cbr\u003e0–30A\n\u003c\/td\u003e\n\u003ctd\u003e\nUDP5800-10\u003cbr\u003e0–10A\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEvery model shares the same chassis architecture, control system, regulation accuracy, protection suite, and interface set. The 800 V UDP5800 tier does not support series connection; all other tiers support series and parallel combining. Choose by the voltage class that covers your rail and the power class that covers your load — output range and chassis height scale with power, the instrument does not change.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"product-key-features\"\u003e\n\u003cli\u003e400W \/ 0–40V \/ 0–40A — auto-ranging across the rated power envelope\u003c\/li\u003e\n\u003cli\u003eVoltage accuracy ±(0.05% of set + 0.05% of rated); current accuracy ±(0.5% of set + 0.1% of rated)\u003c\/li\u003e\n\u003cli\u003eLow ripple — 50mV p-p voltage, 80mA rms current (20 MHz BW)\u003c\/li\u003e\n\u003cli\u003eCC\/CV priority slope modes — choose voltage-first or current-first turn-on for DUT safety\u003c\/li\u003e\n\u003cli\u003eAdjustable internal resistance to 1.000Ω — emulate batteries, fuel cells and solar sources\u003c\/li\u003e\n\u003cli\u003eList Mode — 128 programmable V\/I\/dwell steps, 1 to 9,999, infinite cycles, stand-alone\u003c\/li\u003e\n\u003cli\u003eFront and rear output terminals (front limited to 10 A)\u003c\/li\u003e\n\u003cli\u003eMulti-unit series\/parallel — up to 4 parallel \/ 4 series\u003c\/li\u003e\n\u003cli\u003eUSB + LAN with full SCPI 1999.0 \/ IEEE-488.2; 2.4-inch TFT-LCD\u003c\/li\u003e\n\u003cli\u003eDischarge-load control for rapid output bleed-down\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UDP5040-40 Details\u003c\/h2\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_cc_cv.gif?v=1773763670\" alt=\"CC\/CV priority mode transition behaviour\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eCC\/CV priority mode transition behaviour\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eCC\/CV Priority — Protect the Device, Not Just the Supply\u003c\/h3\u003e\n\u003cp\u003eMost bench supplies treat the CC\/CV crossover as a fixed hardware behaviour. The UDP5000 lets you choose which parameter takes priority at turn-on and during mode transitions. CV-priority establishes the target voltage first — the right choice for microcontrollers, FPGAs and analog rails. CC-priority brings current up under control — the safer choice for LEDs, laser diodes and battery charging where inrush must be bounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_cc_cv.gif?v=1773763670\" alt=\"CC\/CV priority mode transition behaviour\"\u003e\u003cspan class=\"lightbox-caption\"\u003eCC\/CV priority mode transition behaviour\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eAdjustable Slew Rate — Control How Fast Power Arrives\u003c\/h3\u003e\n\u003cp\u003eVoltage and current slew rates are independently settable. A slower ramp prevents inrush into capacitive loads, reduces mechanical stress on motor windings at start-up and gives sensitive analog circuits time to settle; the high-speed default mode is there when fast settling is what the test needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_slew.gif?v=1773763670\" alt=\"Adjustable voltage and current slew rate\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eAdjustable voltage and current slew rate\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_slew.gif?v=1773763670\" alt=\"Adjustable voltage and current slew rate\"\u003e\u003cspan class=\"lightbox-caption\"\u003eAdjustable voltage and current slew rate\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_adjustable_internal_resistance_sq.jpg?v=1773699389\" alt=\"Internal variable resistance source emulation\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eInternal variable resistance source emulation\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eInternal Resistance — Simulate Real Power Sources\u003c\/h3\u003e\n\u003cp\u003eThe internal variable-resistance function (set in CV mode, up to 1.000Ω in 1 mΩ steps) makes the terminal voltage droop with load current exactly as a battery, fuel cell or solar panel would — no physical resistor, no thermal risk, value changeable instantly from the panel or over SCPI.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_adjustable_internal_resistance_sq.jpg?v=1773699389\" alt=\"Internal variable resistance source emulation\"\u003e\u003cspan class=\"lightbox-caption\"\u003eInternal variable resistance source emulation\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eFront \u0026amp; Rear Outputs — Bench-Ready and Rack-Ready\u003c\/h3\u003e\n\u003cp\u003eOutput terminals are provided on both panels. Front terminals are there for quick prototype hookup; rear terminals keep permanent rack wiring clean. Both are the same single output — front-panel draw is limited to 10 A, so high-current loads belong on the rear.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_front_rear_output_sq.jpg?v=1773699389\" alt=\"Front and rear output terminals\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eFront and rear output terminals\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_front_rear_output_sq.jpg?v=1773699389\" alt=\"Front and rear output terminals\"\u003e\u003cspan class=\"lightbox-caption\"\u003eFront and rear output terminals\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_list_sq.jpg?v=1773699389\" alt=\"List Mode programmable output sequencing\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eList Mode programmable output sequencing\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eList Mode \u0026amp; Discharge Control — Automate Output Sequences\u003c\/h3\u003e\n\u003cp\u003eList Mode runs up to 128 programmed V\/I\/dwell steps for 1 to 9,999, infinite cycles or continuously, stored locally or exported, executing with no PC attached — built for overnight burn-in, charge-profile runs and production routines. The internal discharge load bleeds output capacitance down rapidly when output is switched off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_list_sq.jpg?v=1773699389\" alt=\"List Mode programmable output sequencing\"\u003e\u003cspan class=\"lightbox-caption\"\u003eList Mode programmable output sequencing\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eMulti-Unit Operation — Scale When You Need More\u003c\/h3\u003e\n\u003cp\u003eUp to 4 identical units parallel for more current, or up to 4 series for more voltage, coordinated over the rear CAN \/ LS_BUS interface from the master unit or a single SCPI connection; unit-to-unit balance stays within ~5% of rated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_series-parallel.gif?v=1773764029\" alt=\"Multi-unit series and parallel operation\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eMulti-unit series and parallel operation\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_series-parallel.gif?v=1773764029\" alt=\"Multi-unit series and parallel operation\"\u003e\u003cspan class=\"lightbox-caption\"\u003eMulti-unit series and parallel operation\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_front_panel_explainer_sq.jpg?v=1773699389\" alt=\"UDP5000 front panel — 2.4-inch TFT-LCD with multifunction keypad\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eUDP5000 front panel — 2.4-inch TFT-LCD with multifunction keypad\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eDisplay and Control\u003c\/h3\u003e\n\u003cp\u003eA 2.4-inch TFT-LCD presents voltage, current and power simultaneously with a concise multifunction keypad; external analog control (0–10 V setpoint plus digital ON\/OFF) is available on the rear analog interface for closed-loop and HIL setups.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UDP5000_front_panel_explainer_sq.jpg?v=1773699389\" alt=\"UDP5000 front panel — 2.4-inch TFT-LCD with multifunction keypad\"\u003e\u003cspan class=\"lightbox-caption\"\u003eUDP5000 front panel — 2.4-inch TFT-LCD with multifunction keypad\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eBattery and Energy-Storage Test\u003c\/h3\u003e\n\u003cp\u003eThe wide 0–40 V range covers 12 V to 36 V lithium-ion and LFP packs used in e-bike, power-tool and light-EV work. Internal-resistance emulation and List Mode let you reproduce charge profiles and varying pack states without cycling real cells.\u003c\/p\u003e\n\u003ch3\u003eNew-Energy and Automotive Electronics\u003c\/h3\u003e\n\u003cp\u003eDC\/DC converter input stages, inverter front ends and sub-40 V automotive ECUs benefit from the tight regulation, low ripple and CC\/CV priority control.\u003c\/p\u003e\n\u003ch3\u003eAutomated Test and Production\u003c\/h3\u003e\n\u003cp\u003eSCPI over USB or LAN plus stored List Mode sequences make the UDP5000 a clean fit for unattended characterisation, burn-in and end-of-line test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003cp\u003eIn the box: power cord (destination-country standard, 1.8 m), four-conductor analog-interface flat cable (3.5 m), USB cable (1.5 m), M3 mounting screws, output-terminal protection cover, and rack distribution bracket.\u003c\/p\u003e\n\u003cp\u003eThe UDP5000 series spans 16 models on one platform — see \u003cem\u003eChoosing Your Model\u003c\/em\u003e above for the full voltage × power matrix if a different rail or load fits your application better.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eCan I use the front and rear output terminals at the same time?\u003c\/h3\u003e\n\u003cp\u003eBoth terminal sets are parallel connections to the same single output. You can wire both, but the front terminals are limited to 10 A maximum — route high-current loads to the rear panel.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the VHS\/IHS and VSR\/ISR slope modes?\u003c\/h3\u003e\n\u003cp\u003eVHS (CV high-speed) and IHS (CC high-speed) use the supply's default fast rise and fall rates. VSR (CV slope) and ISR (CC slope) let you set the rise and fall rate so output ramps in controlled fashion — useful for capacitive and motor loads, and for sensitive analog circuits that need settling time.\u003c\/p\u003e\n\u003ch3\u003eDoes the internal-resistance function need an external resistor?\u003c\/h3\u003e\n\u003cp\u003eNo. The internal variable-resistance function electronically emulates source impedance (set in CV mode, up to 1.000Ω in 1 mΩ steps), so the supply behaves like a battery, fuel cell or solar source with no physical resistor and no added thermal risk.\u003c\/p\u003e\n\u003ch3\u003eCan multiple units be combined for more power?\u003c\/h3\u003e\n\u003cp\u003eYes. Identical models combine for more current (parallel, up to 4 units) or more voltage (series, up to 4 units), controlled from the master unit or a single SCPI connection; unit-to-unit balance stays within ~5% of rated.\u003c\/p\u003e\n\u003ch3\u003eHow does it integrate with automated test?\u003c\/h3\u003e\n\u003cp\u003eUSB and LAN with full SCPI 1999.0 \/ IEEE-488.2 support LabVIEW, Python-VISA and any standard ATE framework; List Mode runs stored sequences stand-alone without a connected PC.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUDP5040-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 (single channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–40V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Adjustable Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Adjustable Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Setting Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Setting Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Display Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Display Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Output Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.05% of set + 0.05% of rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Output Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.5% of set + 0.1% of rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Load Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±6mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Line Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±6mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Load Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±13mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Line Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±6mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Ripple (p-p, 20 MHz BW)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Ripple (rms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Ripple (rms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time (rated load)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;50ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFall Time (rated load)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;50ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFall Time (no load)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Internal Resistance (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.000Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Sense Compensation (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreset Memory Groups\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList Mode Groups\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList Mode Step Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1s to 99,999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList Mode Cycles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 9,999, infinite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Series-Connected Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Parallel-Connected Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOVP, OCP, FOCP, OTP, Power Limit, Watchdog, Output ON\/OFF Delayer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Device, USB-Host, LAN, Analog I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSCPI \/ IEEE-488.2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (SCPI 1999.0 + IEEE-488.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85-265 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency (typ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.99 @100Vac, 0.97 @200Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4in TFT-LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFan-forced air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20% to 85% R.H. (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=113\"\u003eUDP5040-40 Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":48660726055051,"sku":"181400100250X","price":1189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/5387\/6875\/files\/UDP5000-400W_1.jpg?v=1785212083"},{"product_id":"usg3065v-p-6-5-ghz-vector-rf-signal-generator-with-mechanical-attenuator","title":"USG3065V-P 6.5 GHz Vector RF Signal Generator with Mechanical Attenuator","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe USG3065V is a 6.5 GHz vector signal generator covering 9 kHz to 6.5 GHz with 0.001 Hz frequency resolution and a level range of −135 dBm to +25 dBm. Single-sideband phase noise typically \u0026lt; −122 dBc\/Hz at 1 GHz \/ 20 kHz offset, amplitude accuracy ≤0.7 dB (Typ.), and frequency switching ≤40 ms make it suitable for both bench R\u0026amp;D and automated test workflows. The USG3065V supports full vector modulation with a 150 MHz real-time baseband bandwidth.\u003c\/p\u003e\n\u003cp\u003eAs a vector signal generator, the USG3065V adds a full real-time digital modulation engine to the analog signal-source foundation. With 150 MHz of baseband bandwidth, real-time QAM\/PSK\/FSK\/ASK generation, ARB waveform-file playback, multi-carrier and multi-tone modes, and AWGN noise injection for receiver testing, the USG3065V addresses protocol-aware wireless R\u0026amp;D and commercial production test for 5G NR, WLAN, LTE, Bluetooth, ZigBee, and Z-Wave devices. Typical QPSK EVM is 0.4% at a 1 GHz carrier; 5G NR ACPR is typically \u0026lt; −55 dBc at a 3.8 GHz carrier. The USG3065V is suited to wireless-device R\u0026amp;D, calibration labs running spec verification, and commercial production-test stations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 kHz to 6.5 GHz CW Frequency Range\u003c\/strong\u003e — \u0026gt;5 MHz to 6 GHz in I\/Q mode; 0.001 Hz resolution across the full band.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e−135 dBm to +25 dBm Level Range\u003c\/strong\u003e — 160 dB dynamic range with 0.01 dB resolution and ≤0.7 dB amplitude accuracy typical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Noise \u0026lt; −122 dBc\/Hz at 1 GHz\u003c\/strong\u003e — single-sideband phase noise typical at 20 kHz offset for sensitive vector measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Step Attenuator Standard\u003c\/strong\u003e — 0 to 110 dB range with 10 dB steps; electronic attenuator switches faster with no moving contacts for high-cycle automation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVector Modulation Accuracy\u003c\/strong\u003e — QPSK EVM 0.4% at 1 GHz typical; 5G NR ACPR \u0026lt; −55 dBc at 3.8 GHz typical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150 MHz Real-Time Baseband Bandwidth\u003c\/strong\u003e — internal vector engine covers wideband modulation envelopes including Wi-Fi 6\/7 channel widths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Digital Modulation\u003c\/strong\u003e — QAM, PSK, FSK, ASK with custom filter shapes (RRC, Gaussian, user-defined) and filling settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eARB Playback, Multi-Carrier, and Multi-Tone Modes\u003c\/strong\u003e — user-defined waveform replay with carrier-aggregated and multi-tone test signal generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time AWGN Injection\u003c\/strong\u003e — precise SNR control for receiver sensitivity and dynamic-range characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative ZigBee and Z-Wave IoT Generation\u003c\/strong\u003e — protocol-aware signal generation for IoT module test and incoming inspection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMobile-Comm Protocol Simulation\u003c\/strong\u003e — 5G NR, WLAN, LTE, Bluetooth, IoT waveform support with UNI-T SignalStudio software (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAM, FM, and ΦM Analog Modulation\u003c\/strong\u003e — internal, external, or internal + external sources alongside the digital engine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOCXO High-Stability Clock Source Standard\u003c\/strong\u003e — ≤±0.2 ppm\/year aging, ≤±10 ppb temperature effects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in 50 MHz Function\/Arbitrary Waveform Generator\u003c\/strong\u003e — standard waveforms, sweep, and modulation from a separate LF output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5-Inch Touch Screen with Signal-Flow Interface\u003c\/strong\u003e — full touch control with intuitive signal-flow-diagram interaction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLAN, USB Host, USB Device, I\/Q Baseband I\/O Standard\u003c\/strong\u003e — full SCPI automation via LabVIEW, Python, MATLAB, Excel; GPIB available as a factory-installed hardware option (must be ordered with the instrument).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Control + Device Manager\u003c\/strong\u003e — browser-based remote access plus free PC management software (V2.5.0+).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Pulse Modulation\u003c\/strong\u003e — 80 dB on-off ratio with customizable pulse trains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Narrow-Pulse Generator\u003c\/strong\u003e — 40 ns minimum width with 10 ns resolution for radar component test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional USB Power Sensor Support (USG3000-PK)\u003c\/strong\u003e — license-activated readback and flatness correction with a user-supplied USB power sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE | cETLus | RoHS Compliant\u003c\/strong\u003e — meets common North American and European safety and environmental standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eHigh Spectral Purity for Sensitive Receiver and Component Test\u003c\/h3\u003e\n\u003cp\u003eSingle-sideband phase noise typically below −122 dBc\/Hz at 1 GHz with a 20 kHz offset is the headline spectral-purity figure that determines whether a generator can stimulate the device under test without contaminating the measurement. Low close-in phase noise matters for adjacent-channel rejection testing on receivers, image-rejection on mixers, and any narrowband filter characterization where the stimulus must be cleaner than the device's own passband behavior.\u003c\/p\u003e\n\u003cp\u003eThe clock-source architecture supports ≤±0.2 ppm\/year aging rate, ≤±10 ppb temperature effects, and ≤±10 ppb line-voltage sensitivity — frequency reference stable enough for calibration-cycle use without external 10 MHz lock, though both 10 MHz reference input and 10 MHz output are available on the rear panel for multi-instrument synchronization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-phase_noise.jpg\" alt=\"Phase noise measurement plot for USG3000-series RF generator\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eSingle-sideband phase noise typical \u0026lt; -122 dBc\/Hz at 1 GHz\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-phase_noise.jpg\" alt=\"Phase noise measurement plot for USG3000-series RF generator\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eSingle-sideband phase noise typical \u0026lt; -122 dBc\/Hz at 1 GHz\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-vector_modulation.gif\" alt=\"USG3000V vector modulation display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eQPSK EVM 0.4% at 1 GHz, 5G NR ACPR \u0026lt;-55 dBc at 3.8 GHz (Typ.)\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-vector_modulation.gif\" alt=\"USG3000V vector modulation display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eQPSK EVM 0.4% at 1 GHz, 5G NR ACPR \u0026lt;-55 dBc at 3.8 GHz (Typ.)\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eReal-Time Vector Modulation with 150 MHz Baseband Bandwidth\u003c\/h3\u003e\n\u003cp\u003eThe internal vector engine provides 150 MHz of real-time baseband bandwidth and generates real-time QAM, PSK, FSK, and ASK modulation with user-configurable filter shapes (RRC, Gaussian, custom). User-defined custom modulation types with adjustable filling settings extend coverage across all critical communication formats. With QPSK at a 1 GHz carrier, measured EVM is 0.4% typical — calibration-grade. For 5G NR at 3.8 GHz, ACPR is \u0026lt; −55 dBc typical, so the instrument's own spectral regrowth doesn't dominate measurements on 5G receiver and transmitter validation work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V_2.png\" alt=\"USG3000V front panel showing level control\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e160 dB output range with three ALC modes\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V_2.png\" alt=\"USG3000V front panel showing level control\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e160 dB output range with three ALC modes\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eWide Output Range — +25 dBm Maximum, −135 dBm Minimum\u003c\/h3\u003e\n\u003cp\u003eOutput settable range is −135 dBm to +25 dBm with 0.01 dB resolution. Maximum output power varies by frequency band and attenuator type: in the 250 MHz to 1.2 GHz band, the electronic attenuator delivers +20 dBm typical, while the mechanical attenuator option reaches +24 dBm. Above 1.2 GHz and through 3.6 GHz, electronic output is +18 dBm; mechanical-attenuator output is +22 dBm.\u003c\/p\u003e\n\u003cp\u003eThree ALC (Automatic Level Control) modes are available: ALC Auto selects the optimum mode for the current operating state; ALC On runs closed-loop level control for CW, FM, and ΦM operation; ALC S\u0026amp;H (Off) freezes the closed-loop value on frequency or amplitude transitions, useful for AM and pulse modulation work where ALC interaction with the modulation envelope is undesirable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-scanning_methods.gif\" alt=\"USG3000V ARB and multi-carrier mode displays\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eARB playback with multi-carrier and multi-tone modes\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-scanning_methods.gif\" alt=\"USG3000V ARB and multi-carrier mode displays\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eARB playback with multi-carrier and multi-tone modes\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eARB Playback, Multi-Carrier, and Multi-Tone Modes\u003c\/h3\u003e\n\u003cp\u003eARB playback mode plays back user-defined arbitrary waveform data at variable sampling rates, with baseband preview that displays the waveform in both time and frequency domains before transmission. ARB multi-carrier mode splits wideband signals into multiple narrowband subcarriers, each independently modulated — simplifying construction of carrier-aggregated LTE\/5G NR signals and multi-channel interference environments without external signal combiners. Multi-tone mode generates multiple frequency components simultaneously for intermodulation distortion testing, multi-channel receiver characterization, and spectrum-density emulation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eReal-Time AWGN Injection for Receiver Sensitivity Testing\u003c\/h3\u003e\n\u003cp\u003eThe instrument provides both pure-noise output and real-time additive white Gaussian noise injection, with precise signal-to-noise power control — no separate noise measurement step required before each test. For receiver sensitivity verification, blocking and selectivity testing, and dynamic-range characterization, AWGN injection is the workhorse stimulus. Controlling SNR digitally inside the same instrument that generates the modulated signal removes a measurement-uncertainty drift source on long-running production sequences.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-AWGN_white_guassian_noise.gif\" alt=\"USG3000V AWGN spectrum display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eReal-time AWGN injection with precise SNR control\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-AWGN_white_guassian_noise.gif\" alt=\"USG3000V AWGN spectrum display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eReal-time AWGN injection with precise SNR control\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-signal_studio_support.gif\" alt=\"USG3000V SignalStudio software upper-computer interface\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNative ZigBee, Z-Wave + 5G NR\/WLAN\/LTE\/Bluetooth via SignalStudio\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-signal_studio_support.gif\" alt=\"USG3000V SignalStudio software upper-computer interface\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNative ZigBee, Z-Wave + 5G NR\/WLAN\/LTE\/Bluetooth via SignalStudio\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eIoT and Mobile Communication Protocol Generation\u003c\/h3\u003e\n\u003cp\u003eNative ZigBee and Z-Wave signal generation is built into the instrument's vector engine with flexible modulation parameter settings per protocol — eliminating third-party IoT signal source dependencies for incoming inspection, R\u0026amp;D prototyping, and production-line stimulus. For 5G NR, WLAN, LTE, and Bluetooth waveforms, the instrument pairs with UNI-T's SignalStudio software (sold separately) for protocol-compliant signal simulation across commercial wireless-device R\u0026amp;D and compliance pre-screen.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eOptional Pulse and Narrow-Pulse Generation\u003c\/h3\u003e\n\u003cp\u003eThe optional pulse modulation package adds an on-off ratio of up to 80 dB with customizable pulse-train definitions, enabling single-instrument pulsed RF for radar component test, time-gated stimulus, and EMC pulsed-emission work. The narrow-pulse generator option extends capability to a 40 ns minimum width with 10 ns resolution, addressing test requirements of millimeter-wave radar components used in commercial automotive ADAS suppliers and short-range industrial radar systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000M-USG5000M_pulse.png\" alt=\"USG3000V pulse modulation output waveform\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003ePulse modulation with 80 dB on-off ratio and narrow-pulse generation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000M-USG5000M_pulse.png\" alt=\"USG3000V pulse modulation output waveform\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003ePulse modulation with 80 dB on-off ratio and narrow-pulse generation\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUSB Power Sensor Support — Flatness Correction at the DUT Plane (Option USG3000-PK)\u003c\/h3\u003e\n\u003cp\u003eThe optional \u003cstrong\u003eUSG3000-PK\u003c\/strong\u003e software license enables the instrument to read and display power measurements from a user-supplied USB power sensor connected to the front-panel USB Host port. The license is delivered as a file that installs from a USB stick via the instrument's Option Install menu, following the same activation workflow as the Pulse Modulation and GPIB options. A USB power sensor is not included; the user supplies a compatible sensor.\u003c\/p\u003e\n\u003cp\u003eOnce activated, the Power Sensor menu provides measurement frequency entry, frequency coupling to the current RF carrier (with multiplier and offset for harmonic and IF-shifted measurements), measurement averaging, and amplitude offset entry — the standard tools for flatness correction and cable-loss compensation at the DUT plane. The amplitude offset entry is particularly useful when the signal path between the generator and the device under test includes cables, attenuators, or amplifiers: the displayed power reflects what the DUT actually sees, not what leaves the generator's output connector.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-power_de-embedding.jpg\" alt=\"USG3000V USB power sensor measurement and path-loss compensation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eLicense-activated USB power sensor support — user supplies sensor\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-power_de-embedding.jpg\" alt=\"USG3000V USB power sensor measurement and path-loss compensation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLicense-activated USB power sensor support — user supplies sensor\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e5-Inch Touch UI with Signal-Flow Interface\u003c\/h3\u003e\n\u003cp\u003eA 5.0-inch high-resolution touch screen provides full touch control over every function except the power switch. The interface is built around a signal-flow diagram — the user sees modulation source, modulation type, sweep mode, and RF carrier as a connected chain rather than as scattered menu items. For an instrument with this much configurable surface area (multiple modulation paths, multiple sweep modes, multiple digital protocols, ARB and multi-carrier work, optional pulse and power-meter kits), the signal-flow paradigm meaningfully cuts setup time on R\u0026amp;D benches where the test configuration changes hour-to-hour.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-flat_interface.gif\" alt=\"USG3000V touch UI with flat signal-flow interface\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e5-inch touch screen with signal-flow-guided interface\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-flat_interface.gif\" alt=\"USG3000V touch UI with flat signal-flow interface\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e5-inch touch screen with signal-flow-guided interface\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-computer_interface.gif\" alt=\"USG3000V computer interface and automation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eLAN, USB, GPIB (factory option) with SCPI, Web Control, and Device Manager\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-computer_interface.gif\" alt=\"USG3000V computer interface and automation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLAN, USB, GPIB (factory option) with SCPI, Web Control, and Device Manager\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eFull Automation — SCPI, Web Control, Device Manager\u003c\/h3\u003e\n\u003cp\u003eLAN, USB Host, and USB Device are standard rear-panel interfaces. GPIB is available as a factory-installed hardware option and must be ordered with the instrument. All ports speak the standard SCPI command set, enabling remote operation from any automation-capable host. Test engineers commonly drive the instrument from LabVIEW, Python, MATLAB, or even Excel macros for batch command execution.\u003c\/p\u003e\n\u003cp\u003eWeb Control provides browser-based remote access — point a PC or mobile browser at the instrument's IP address and the full front-panel UI is available remotely, with no client install. Device Manager (UNI-T's free PC software, V2.5.0 and higher) manages the instrument via LAN (VXI-11, Socket), USB Device (USB-TMC), or GPIB, and handles batch instrument inventories on a multi-station test floor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Specifications\u003c\/h2\u003e\n\u003ctable class=\"product-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range (CW mode)\u003c\/th\u003e\n\u003ctd\u003e9 kHz to 6.5 GHz (CW mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range (I\/Q mode)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;5 MHz to 6 GHz (I\/Q mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency resolution\u003c\/th\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase offset step\u003c\/th\u003e\n\u003ctd\u003e0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency switching speed\u003c\/th\u003e\n\u003ctd\u003e≤40 ms (SCPI \/ list \/ step sweep)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLevel settable range\u003c\/th\u003e\n\u003ctd\u003e-135 dBm to +25 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLevel resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplitude accuracy (Typ.)\u003c\/th\u003e\n\u003ctd\u003e≤0.7 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAttenuator type\u003c\/th\u003e\n\u003ctd\u003eElectronic attenuator standard (0 to 110 dB, 10 dB steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise (Typ.)\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;-122 dBc\/Hz @ 1 GHz, 20 kHz offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOscillator aging rate\u003c\/th\u003e\n\u003ctd\u003e≤ ±0.2 ppm\/year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature effects\u003c\/th\u003e\n\u003ctd\u003e≤ ±10 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInitial calibration accuracy\u003c\/th\u003e\n\u003ctd\u003e≤ ±40 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalog modulation\u003c\/th\u003e\n\u003ctd\u003eAM, FM, ΦM (internal \/ external \/ internal+external)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDigital modulation\u003c\/th\u003e\n\u003ctd\u003eQAM, PSK, FSK, ASK (real-time digital standard formats; custom modulation supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBaseband bandwidth\u003c\/th\u003e\n\u003ctd\u003e150 MHz real-time baseband bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVector modulation EVM (Typ.)\u003c\/th\u003e\n\u003ctd\u003eQPSK EVM 0.4% at 1 GHz carrier (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e5G NR ACPR (Typ.)\u003c\/th\u003e\n\u003ctd\u003e5G NR ACPR \u0026lt;-55 dBc at 3.8 GHz carrier (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eARB modes\u003c\/th\u003e\n\u003ctd\u003eARB playback, ARB multi-carrier, multi-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise injection\u003c\/th\u003e\n\u003ctd\u003eAWGN (additive white Gaussian noise) for receiver testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIoT protocols (native)\u003c\/th\u003e\n\u003ctd\u003eZigBee, Z-Wave (IoT signal generation and playback)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMobile-comm protocol simulation\u003c\/th\u003e\n\u003ctd\u003e5G NR, WLAN, LTE, Bluetooth, IoT (with SignalStudio software, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse modulation (option)\u003c\/th\u003e\n\u003ctd\u003e80 dB on-off ratio, customizable pulse trains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNarrow pulse (option)\u003c\/th\u003e\n\u003ctd\u003eMin width \/ resolution: 40 ns \/ 10 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSB power sensor (option USG3000-PK)\u003c\/th\u003e\n\u003ctd\u003eLicense-activated; flatness correction with user-supplied USB power sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSweep modes\u003c\/th\u003e\n\u003ctd\u003eStep sweep, list sweep (frequency, amplitude)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStep sweep points\u003c\/th\u003e\n\u003ctd\u003e2 to 65535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eList sweep points\u003c\/th\u003e\n\u003ctd\u003e1 to 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDwell time\u003c\/th\u003e\n\u003ctd\u003e100 μs to 100 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBuilt-in AWG\u003c\/th\u003e\n\u003ctd\u003e50 MHz function \/ arbitrary waveform generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference (10 MHz)\u003c\/th\u003e\n\u003ctd\u003e10 MHz (in\/out, 50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5.0-inch touch screen, signal-flow-guided interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard interfaces\u003c\/th\u003e\n\u003ctd\u003eLAN, USB Host, USB Device, I\/Q baseband I\/O (GPIB optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRemote control\u003c\/th\u003e\n\u003ctd\u003eSCPI, Web Control (browser), Device Manager (PC software, V2.5.0+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRoHS\u003c\/th\u003e\n\u003ctd\u003eCompliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications subject to change without notice. \"Typ.\" values represent typical performance and are not warranted.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eProtocol-Aware Wireless Device Development\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5G NR Mid-Band and Wi-Fi 6E\/7 Development\u003c\/strong\u003e — 6.5 GHz coverage spans 5G NR mid-band, Wi-Fi 6E\/7 (6 GHz unlicensed band), and commercial V2X communication test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQAM, PSK, FSK, ASK Real-Time Digital Modulation\u003c\/strong\u003e — Custom filter shapes (RRC, Gaussian, user-defined) for protocol-specific test signal generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eARB Multi-Carrier Mode\u003c\/strong\u003e — Carrier-aggregated LTE \/ 5G NR test signals without external combiners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAWGN Injection\u003c\/strong\u003e — Real-time noise injection for receiver sensitivity and dynamic-range characterization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial Production Test and Calibration Labs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 GHz Commercial Module Verification\u003c\/strong\u003e — Production verification of Wi-Fi 6E\/7 access points, 5G NR mid-band CPE, and ZigBee\/Z-Wave IoT modules with built-in protocol generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration-Grade Vector Modulation Accuracy\u003c\/strong\u003e — QPSK EVM 0.4% typical at 1 GHz supports commercial cal-lab spec verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Power Sensor Integration\u003c\/strong\u003e — Optional USG3000-PK license activates flatness correction at the DUT plane with a user-supplied USB power sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOCXO Clock Source Standard\u003c\/strong\u003e — ≤±0.2 ppm\/year aging suits calibration-cycle scheduling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIoT Device R\u0026amp;D and Compliance Pre-Screen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 GHz IoT and Industrial Wireless Test\u003c\/strong\u003e — Next-generation IoT mesh systems and commercial industrial wireless above the 5 GHz band.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative ZigBee and Z-Wave Generation\u003c\/strong\u003e — Flexible modulation parameter control (modulation count, modulation method) per protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignalStudio Protocol Simulation\u003c\/strong\u003e — 5G NR \/ WLAN \/ LTE \/ Bluetooth waveform support via UNI-T SignalStudio software (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Tone Mode\u003c\/strong\u003e — IoT mesh-network coexistence and interference testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUSG3065V RF signal generator\u003c\/li\u003e\n\u003cli\u003eAC power cord (region-specific)\u003c\/li\u003e\n\u003cli\u003eUSB data cable\u003c\/li\u003e\n\u003cli\u003eQuick start guide and certificate of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSG3000-PM\u003c\/strong\u003e — Pulse modulation option (license-activated; 80 dB on-off ratio, customizable pulse trains).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSG3000-PG\u003c\/strong\u003e — Narrow-pulse generator option (license-activated; 40 ns minimum width, 10 ns resolution).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSG3000-PK\u003c\/strong\u003e — USB power sensor support option (license-activated; user supplies a compatible USB power sensor).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSG3000-GPIB\u003c\/strong\u003e — GPIB interface hardware option; adds a factory-installed IEEE 488 port for legacy automation systems. Must be ordered with the instrument — cannot be added after purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignalStudio + waveform licenses\u003c\/strong\u003e — UNI-T SignalStudio software (sold separately) with optional waveform-playback license packages: BT (Bluetooth), OFDM (custom OFDM), DM (custom digital modulation), VIOT (extended IoT).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSMA cables and adapters\u003c\/strong\u003e — UT-W01-6GHz NJ-NJ DC-6 GHz cable, UT-W02-6GHz SMAJ-NJ DC-6 GHz cable, UT-C01-6GHz SMA-N adapter, UT-C02-4GHz N-BNC adapter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUSG3045M — 4.5 GHz analog, electronic attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG3045M-P — 4.5 GHz analog, mechanical attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG3065M — 6.5 GHz analog, electronic attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG3065M-P — 6.5 GHz analog, mechanical attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG3045V — 4.5 GHz vector, electronic attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG3045V-P — 4.5 GHz vector, mechanical attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG3065V-P — 6.5 GHz vector, mechanical attenuator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between the V-series and the M-series?\u003c\/p\u003e\n\u003cp\u003eThe M-series is an analog RF signal generator (AM, FM, ΦM with optional pulse and narrow-pulse modulation) suited to amplifier and filter R\u0026amp;D, receiver calibration, and pulsed-RF component test. The V-series adds a full real-time digital modulation engine on the same analog foundation: 150 MHz baseband bandwidth, QAM\/PSK\/FSK\/ASK, ARB playback with multi-carrier, AWGN injection, and native ZigBee\/Z-Wave IoT generation. SignalStudio software (sold separately) extends V-series coverage to 5G NR\/WLAN\/LTE\/Bluetooth. M addresses component-level stimulus; V addresses protocol-aware wireless device development.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between the USG3065V and the −P variant?\u003c\/p\u003e\n\u003cp\u003eThe USG3065V ships with an electronic step attenuator as standard; the −P variant substitutes a mechanical step attenuator. Both provide 0–110 dB range with 10 dB steps. Mechanical attenuators deliver higher absolute output power (~+4 dB above electronic at the 250 MHz–3.6 GHz bands); electronic attenuators switch faster and have longer service life. Choose mechanical for maximum output headroom, electronic for high-cycle automation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat automation interfaces are standard?\u003c\/p\u003e\n\u003cp\u003eLAN, USB Host, and USB Device are standard rear-panel interfaces. GPIB is available as a factory-installed hardware option (must be ordered with the instrument). All ports support the standard SCPI command set, so the instrument drops into any existing automated test station (LabVIEW, Python, MATLAB, Excel) without protocol translation. Web Control provides browser-based remote access via the instrument's IP address — no client install required, works from PC and mobile. UNI-T's free Device Manager PC software (V2.5.0 and higher) handles batch instrument inventories via LAN (VXI-11, Socket), USB Device (USB-TMC), or GPIB.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat does the USG3000-PK power sensor option provide?\u003c\/p\u003e\n\u003cp\u003eUSG3000-PK is a software license that activates USB power sensor support in the instrument. The user connects a compatible USB-TMC power sensor (sold separately) to the front-panel USB Host port; the instrument displays the power measurement on its own screen with menu controls for measurement frequency, frequency coupling (multiplier + offset), amplitude offset for path-loss compensation, and averaging. The primary use case is flatness correction and cable-loss compensation at the DUT plane — the amplitude offset entry compensates for cables and adapters between the generator and the device under test. License is activated via UNI-T's standard option-install workflow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range (CW mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 6.5 GHz (CW mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range (I\/Q mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;5 MHz to 6 GHz (I\/Q mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase offset step\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency switching speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤40 ms (SCPI \/ list \/ step sweep)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLevel settable range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-135 dBm to +25 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLevel resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude accuracy (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.7 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuator type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanical step attenuator standard (0 to 110 dB, 10 dB steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;-122 dBc\/Hz @ 1 GHz, 20 kHz offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOscillator aging rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ ±0.2 ppm\/year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature effects\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ ±10 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitial calibration accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ ±40 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog modulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAM, FM, ΦM (internal \/ external \/ internal+external)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital modulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQAM, PSK, FSK, ASK (real-time digital standard formats; custom modulation supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaseband bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 MHz real-time baseband bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVector modulation EVM (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQPSK EVM 0.4% at 1 GHz carrier (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5G NR ACPR (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5G NR ACPR \u0026lt;-55 dBc at 3.8 GHz carrier (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eARB modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eARB playback, ARB multi-carrier, multi-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise injection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWGN (additive white Gaussian noise) for receiver testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIoT protocols (native)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZigBee, Z-Wave (IoT signal generation and playback)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobile-comm protocol simulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5G NR, WLAN, LTE, Bluetooth, IoT (with SignalStudio software, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse modulation (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 dB on-off ratio, customizable pulse trains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNarrow pulse (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMin width \/ resolution: 40 ns \/ 10 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB power sensor (option USG3000-PK)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLicense-activated; flatness correction with user-supplied USB power sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStep sweep, list sweep (frequency, amplitude)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStep sweep points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 to 65535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList sweep points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDwell time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 μs to 100 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz function \/ arbitrary waveform generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference (10 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MHz (in\/out, 50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0-inch touch screen, signal-flow-guided interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLAN, USB Host, USB Device, I\/Q baseband I\/O (GPIB optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI, Web Control (browser), Device Manager (PC software, V2.5.0+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=121\"\u003eUSG3065V-P Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUSG3000-GPIB — GPIB Adapter Option\u003c\/li\u003e\n  \u003cli\u003eUSG3000-PG — Narrow Pulse Generator Option\u003c\/li\u003e\n  \u003cli\u003eUSG3000-PK — Power Meter Option\u003c\/li\u003e\n  \u003cli\u003eUSG3000-PM — Pulse Modulation Option\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":48660726612107,"sku":"181300200033X","price":21999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/5387\/6875\/files\/USG3000V_1_sq.jpg?v=1785212094"},{"product_id":"uts7026a-26-5-ghz-interceptor-series-signal-analyzer","title":"UTS7026A 26.5 GHz Interceptor-Series Signal Analyzer","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTS7026A\u003c\/strong\u003e is a 26.5 GHz signal analyzer for commercial wireless, IoT, EMI pre-compliance, and R\u0026amp;D characterization work. It covers 2 Hz – 26.5 GHz on a single chassis, with −167 dBm\/Hz displayed average noise level (DANL with preamplifier engaged) and 100,001 sweep points across the span.\u003c\/p\u003e\n\u003cp\u003eThe UTS7026A is a 26.5 GHz member of the UTS7000A wide-band signal analyzer line. Real-time spectrum analysis is included as a base instrument capability with 40 MHz analysis bandwidth standard, software-expandable to 85, 160, or 255 MHz via the B-series license options. A full ecosystem of measurement options — 5G NR demodulation, vector signal analysis, I\/Q capture, EMI pre-compliance, phase noise, advanced power measurements, analog demodulation, and LTE FDD\/TDD — expands the same hardware platform to specialized workflows without buying a second instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — UTS7000A Series\u003c\/h2\u003e\n\u003cp\u003eThe UTS7000A name spans eight models on one signal-analyzer platform. The series splits into two configurations: a wide-band configuration (40 MHz baseline real-time bandwidth, software-expandable to 255 MHz) and a narrow-band –NB configuration (20 MHz fixed real-time bandwidth, no upgrade path). Sampling, sweep points, phase noise, DANL, display, interface, and option compatibility are identical across all eight models. Choose the maximum frequency your work requires, then choose the bandwidth configuration.\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:22%\"\u003e\n\u003ccol style=\"width:24%\"\u003e\n\u003ccol style=\"width:32%\"\u003e\n\u003ccol style=\"width:22%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eMax Frequency\u003c\/th\u003e\n\u003cth\u003eReal-Time Bandwidth\u003c\/th\u003e\n\u003cth\u003ePaired Preamplifier\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"4\" class=\"cohort-label\"\u003e\u003cstrong\u003eUTS7000A — Wide-Band Configuration (40 MHz RTSA, software-expandable to 255 MHz)\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTS7013A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Hz – 13.6 GHz\u003c\/td\u003e\n\u003ctd\u003e40 MHz baseline; B85 \/ B160 \/ B255 options\u003c\/td\u003e\n\u003ctd\u003eUTS7000A-P13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTS7026A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Hz – 26.5 GHz\u003c\/td\u003e\n\u003ctd\u003e40 MHz baseline; B85 \/ B160 \/ B255 options\u003c\/td\u003e\n\u003ctd\u003eUTS7000A-P26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTS7032A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Hz – 32 GHz\u003c\/td\u003e\n\u003ctd\u003e40 MHz baseline; B85 \/ B160 \/ B255 options\u003c\/td\u003e\n\u003ctd\u003eUTS7000A-P32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTS7040A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Hz – 40 GHz\u003c\/td\u003e\n\u003ctd\u003e40 MHz baseline; B85 \/ B160 \/ B255 options\u003c\/td\u003e\n\u003ctd\u003eUTS7000A-P40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"4\" class=\"cohort-label\"\u003e\u003cstrong\u003eUTS7000A–NB — Narrow-Band Configuration (20 MHz RTSA, fixed, no upgrade path)\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTS7013A–NB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Hz – 13.6 GHz\u003c\/td\u003e\n\u003ctd\u003e20 MHz fixed\u003c\/td\u003e\n\u003ctd\u003eUTS7000A-P13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTS7026A–NB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Hz – 26.5 GHz\u003c\/td\u003e\n\u003ctd\u003e20 MHz fixed\u003c\/td\u003e\n\u003ctd\u003eUTS7000A-P26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTS7032A–NB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Hz – 32 GHz\u003c\/td\u003e\n\u003ctd\u003e20 MHz fixed\u003c\/td\u003e\n\u003ctd\u003eUTS7000A-P32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTS7040A–NB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Hz – 40 GHz\u003c\/td\u003e\n\u003ctd\u003e20 MHz fixed\u003c\/td\u003e\n\u003ctd\u003eUTS7000A-P40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eChoose the narrow-band –NB configuration when your signals do not require real-time bandwidth beyond 20 MHz — narrow-channel monitoring, single-carrier characterization, slow-hopping signal capture, or EMI pre-compliance on conducted-emissions spans. Choose the wide-band configuration when wideband real-time capture matters: multi-carrier signals, 5G NR FR2 component carriers, wideband modulated payloads, or transient capture across spans up to 255 MHz.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"product-key-features\"\u003e\n\u003cli\u003eFrequency range 2 Hz to 26.5 GHz, single chassis, no band switching\u003c\/li\u003e\n\u003cli\u003e−167 dBm\/Hz displayed average noise level with the UTS7000A-P26 preamplifier engaged\u003c\/li\u003e\n\u003cli\u003ePhase noise \u0026lt;−110 dBc\/Hz\u003c\/li\u003e\n\u003cli\u003eReal-time spectrum analysis included — 40 MHz baseline, software-expandable to 85, 160, or 255 MHz\u003c\/li\u003e\n\u003cli\u003e100,001 sweep points, six traces, 1 Hz to 10 MHz RBW range\u003c\/li\u003e\n\u003cli\u003e11.6-inch TFT-LCD touchscreen with full front-panel keyboard\u003c\/li\u003e\n\u003cli\u003eUSB 3.0, USB 2.0, LAN, HDMI, 10 MHz reference In\/Out, dual trigger inputs\u003c\/li\u003e\n\u003cli\u003eNine software-licensed measurement options on one platform — 5G NR, VSA, I\/Q, EMI, PNM, AMA, AMK, FDD-LTE, TDD-LTE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\u003ch2\u003eUNI-T UTS7026A Details\u003c\/h2\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1748898581\/UTS7000A-bandwidth.jpg\" alt=\"UTS7000A real-time bandwidth display showing modulated signal capture\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eReal-time bandwidth display — modulated signal capture in a single record\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eReal-Time Spectrum Analysis — 40 MHz Standard, Software-Expandable to 255 MHz\u003c\/h3\u003e\n\u003cp\u003eReal-time spectrum analysis is part of the base instrument. The UTS7026A ships configured for 40 MHz of real-time analysis bandwidth and achieves 100% frequency-domain signal capture in under 3.21 µs, so transient and intermittent signals that a swept analyzer would miss are captured into the trace. The instrument supports density spectrum, spectrogram (waterfall), and Power-vs-Time displays simultaneously, plus a Frequency Mask Template (FMT) trigger for capture on signal arrival, departure, or shape change.\u003c\/p\u003e\n\u003cp\u003eWider real-time bandwidth is added by software license without changing chassis. The UTS7000A-B85 raises the real-time bandwidth to 85 MHz, the UTS7000A-B160 to 160 MHz, and the UTS7000A-B255 to 255 MHz — sufficient to capture 5G NR FR2 component carriers and wideband modulated payloads in a single record. The license unlock is field-installable on any 40 MHz wide-band UTS7000A chassis and remains permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1748898581\/UTS7000A-bandwidth.jpg\" alt=\"UTS7000A real-time bandwidth display showing modulated signal capture\"\u003e\u003cspan class=\"lightbox-caption\"\u003eReal-time bandwidth display — modulated signal capture in a single record\u003c\/span\u003e\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eFrequency Range to 26.5 GHz with Optional Preamplifier\u003c\/h3\u003e\n\u003cp\u003eThe UTS7026A covers 2 Hz – 26.5 GHz on a single chassis — no band switching, no external mixers, no second instrument for the higher-frequency portion of the range. The UTS7000A-P26 preamplifier is the paired sensitivity option for this chassis. With the preamplifier engaged, displayed average noise level reaches −167 dBm\/Hz — the floor that small-signal characterization, near-noise-level demodulation, and weak-emitter EMI work depend on. Each chassis in the UTS7000A line has its own paired preamp matched to the chassis's frequency range; the P26 is correct for the 26.5 GHz chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e5G NR Demodulation Analysis\u003c\/h3\u003e\n\u003cp\u003eThe UTS7000A-NR option adds 5G New Radio demodulation analysis directly on the instrument. Combined with the UTS7026A's 26.5 GHz frequency reach and the real-time bandwidth options up to 255 MHz, the chassis supports commercial 5G NR characterization across sub-6 GHz (FR1) plus the lower portion of FR2 band n258 (24.25–26.5 GHz, the European 26 GHz mmWave band) used in commercial fixed wireless access and base-station equipment development. Higher FR2 bands (n257, n261, n260) require a higher-frequency chassis in the UTS7000A line.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1748898581\/UTS7000A-Communication_analysis.jpg\" alt=\"UTS7000A communications signal analysis display\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eCommunications signal analysis display\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1748898581\/UTS7000A-Communication_analysis.jpg\" alt=\"UTS7000A communications signal analysis display\"\u003e\u003cspan class=\"lightbox-caption\"\u003eCommunications signal analysis display\u003c\/span\u003e\u003cdiv class=\"product-container\"\u003e\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1748898582\/UTS7000A-digital_modulation.jpg\" alt=\"UTS7000A VSA digital modulation constellation\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eDigital modulation analysis — constellation diagram with EVM measurement\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eVector Signal Analysis\u003c\/h3\u003e\n\u003cp\u003eThe UTS7000A-VSA option provides general-purpose vector signal analysis with constellation, EVM, and symbol-rate measurement across the major digital modulation families — PSK, QAM, FSK, MSK, and ASK variants. Symbol rate is set from 1 ksps up to the instrument's analysis bandwidth divided by symbol points. Used for protocol bring-up on custom radios, IQ-based modulation verification, and digital-radio R\u0026amp;D where the modulation scheme is not a standardized cellular waveform.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1748898582\/UTS7000A-digital_modulation.jpg\" alt=\"UTS7000A VSA digital modulation constellation\"\u003e\u003cspan class=\"lightbox-caption\"\u003eDigital modulation analysis — constellation diagram with EVM measurement\u003c\/span\u003e\u003cdiv class=\"product-container\"\u003e\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eI\/Q Signal Analyzer\u003c\/h3\u003e\n\u003cp\u003eThe UTS7000A-I\/Q option captures complex baseband I and Q time-record data alongside the frequency-domain view. The captured I\/Q record supports both time-domain and frequency-domain inspection of the same signal, useful for protocol-level debug, custom-modulation verification, and post-capture analysis in external tools where the raw IQ samples are needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1748898587\/UTS7000A-IQ.jpg\" alt=\"UTS7000A IQ time-record display\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eI\/Q time-record capture display\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1748898587\/UTS7000A-IQ.jpg\" alt=\"UTS7000A IQ time-record display\"\u003e\u003cspan class=\"lightbox-caption\"\u003eI\/Q time-record capture display\u003c\/span\u003e\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eEMI Pre-Compliance Testing\u003c\/h3\u003e\n\u003cp\u003eThe UTS7000A-EMI option configures the instrument for EMI pre-compliance work with CISPR-style detectors (including quasi-peak), pre-defined limit lines, and meter-mode measurement at fixed frequencies. Pre-scan plus final-scan workflows let a development team identify probable emissions failures and characterize their spectral content before scheduling certified-chamber time. Conducted-emissions spans (Band A, Band B) and broader radiated-emissions sweeps are both supported on the same instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1748898588\/UTS7000A-one-button_phase_noise.jpg\" alt=\"UTS7000A one-button phase noise display\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eOne-button phase noise analysis — dBc\/Hz log-plot display\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003ePhase Noise Analysis\u003c\/h3\u003e\n\u003cp\u003eThe UTS7000A-PNM option provides one-touch phase noise measurement at user-selected offset frequencies, with dBc\/Hz log-plot display. Used for oscillator characterization, synthesizer evaluation, and reference-clock qualification where the instrument's own phase noise floor (\u0026lt;−110 dBc\/Hz) is well below the device under test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1748898588\/UTS7000A-one-button_phase_noise.jpg\" alt=\"UTS7000A one-button phase noise display\"\u003e\u003cspan class=\"lightbox-caption\"\u003eOne-button phase noise analysis — dBc\/Hz log-plot display\u003c\/span\u003e\u003cdiv class=\"product-container\"\u003e\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eAdvanced Measurement Kit — TOI, OBW, Channel Power, ACPR, CNR, Spectrum Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe UTS7000A-AMK option adds a set of one-touch power and spectral measurements for routine RF characterization work — third-order intercept (TOI), occupied bandwidth (OBW), channel power, adjacent-channel power ratio (ACPR), carrier-to-noise ratio (CNR), harmonic analysis, time-domain power, and spectrum monitoring. Each is a dedicated measurement screen rather than a manual sequence of marker placements, which is the practical difference for production-floor characterization and overnight automated sweeps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTS7000A_AMK_Functions.gif?v=1779288419\" alt=\"UTS7000A Advanced Measurement Kit functions: TOI, OBW, channel power, ACPR, CNR, harmonic analysis, time-domain power, spectrum monitoring\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eAdvanced Measurement Kit — cycling through TOI, OBW, channel power, ACPR, CNR, harmonic, time-domain power, and spectrum monitoring measurements\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTS7000A_AMK_Functions.gif?v=1779288419\" alt=\"UTS7000A Advanced Measurement Kit functions: TOI, OBW, channel power, ACPR, CNR, harmonic analysis, time-domain power, spectrum monitoring\"\u003e\u003cspan class=\"lightbox-caption\"\u003eAdvanced Measurement Kit — cycling through TOI, OBW, channel power, ACPR, CNR, harmonic, time-domain power, and spectrum monitoring measurements\u003c\/span\u003e\u003cdiv class=\"product-container\"\u003e\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1748898581\/UTS7000A-analog_modulation.jpg\" alt=\"UTS7000A analog modulation analysis\" class=\"product-image-thumb\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eAnalog modulation analysis — AM\/FM\/PM demodulation\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eAnalog and LTE Demodulation\u003c\/h3\u003e\n\u003cp\u003eThe UTS7000A-AMA option adds analog demodulation analysis for AM, FM, and PM signals, with measurement of carrier, modulation depth, frequency deviation, SINAD, and total harmonic distortion. The UTS7000A-FDD-LTE and UTS7000A-TDD-LTE options add 3GPP LTE demodulation for FDD and TDD signals respectively, with per-resource-block EVM, frame and slot synchronization, PDSCH and PUSCH characterization, and OFDM signal analysis. Each is a separate license and operates as a dedicated measurement mode on the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1748898581\/UTS7000A-analog_modulation.jpg\" alt=\"UTS7000A analog modulation analysis\"\u003e\u003cspan class=\"lightbox-caption\"\u003eAnalog modulation analysis — AM\/FM\/PM demodulation\u003c\/span\u003e\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003ePrimary Applications\u003c\/h2\u003e\n\u003ch3\u003e5G NR Sub-6 and Commercial Wireless Equipment Development\u003c\/h3\u003e\n\u003cp\u003eThe UTS7026A's 26.5 GHz frequency reach covers commercial 5G NR sub-6 (FR1) plus the lower portion of FR2 band n258 (the European 26 GHz mmWave band), supporting commercial base-station development, fixed wireless access equipment, and 5G UE characterization within the n258 allocation. The UTS7000A-NR demodulation option, the real-time bandwidth options up to 255 MHz, and the I\/Q time-record option are the three pieces a typical commercial 5G NR bench will use together.\u003c\/p\u003e\n\u003ch3\u003eWireless and IoT Protocol Bring-Up\u003c\/h3\u003e\n\u003cp\u003eFor 2.4 GHz and 5 GHz commercial bands — Wi-Fi 6 \/ 6E, Bluetooth, Zigbee, LoRa, and custom proprietary radios — the chassis pairs with the UTS7000A-VSA for digital modulation characterization and the UTS7000A-I\/Q for time-record capture used in protocol-level debug and post-capture analysis. Real-time analysis bandwidth options support wideband channels and frequency-hopping signal capture.\u003c\/p\u003e\n\u003ch3\u003eEMI Pre-Compliance and Spectral Hygiene\u003c\/h3\u003e\n\u003cp\u003eThe UTS7000A-EMI option configures the instrument for conducted and radiated emissions pre-compliance work — CISPR-style detectors including quasi-peak, pre-defined limit lines, and pre-scan plus final-scan workflows. For power-electronics designs where switching-frequency emissions and harmonics need to be characterized before chamber time, the combination of EMI option plus the UTS7000A-AMK measurement kit (harmonic analysis, spectrum monitoring) supports a complete pre-compliance bench on one instrument.\u003c\/p\u003e\n\u003ch3\u003eR\u0026amp;D Characterization and Spectrum Monitoring\u003c\/h3\u003e\n\u003cp\u003eFor general signal-analysis R\u0026amp;D work — oscillator and synthesizer phase-noise qualification, intermodulation distortion measurement, spurious search, weak-signal detection, and long-duration spectrum monitoring — the chassis's −167 dBm\/Hz noise floor (with preamp), 100,001 sweep points, six trace memories, and real-time density-spectrum display cover the day-to-day workflows. The UTS7000A-PNM phase noise option and the UTS7000A-AMK measurement kit are the most-used adds for this work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eReal-time bandwidth options\u003c\/strong\u003e (software licenses, wide-band configuration only):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nUTS7000A-B85 — 85 MHz real-time analysis bandwidth\u003c\/li\u003e\n\u003cli\u003e\nUTS7000A-B160 — 160 MHz real-time analysis bandwidth\u003c\/li\u003e\n\u003cli\u003e\nUTS7000A-B255 — 255 MHz real-time analysis bandwidth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaired preamplifier option\u003c\/strong\u003e (frequency-matched to this chassis):\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\nUTS7000A-P26 — preamplifier for UTS7026A and UTS7026A-NB\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement function options\u003c\/strong\u003e (software-licensed; compatible with all UTS7000A chassis including –NB):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nUTS7000A-NR — 5G NR demodulation analysis\u003c\/li\u003e\n\u003cli\u003e\nUTS7000A-VSA — vector signal analysis\u003c\/li\u003e\n\u003cli\u003e\nUTS7000A-I\/Q — I\/Q signal analyzer\u003c\/li\u003e\n\u003cli\u003e\nUTS7000A-EMI — EMI pre-compliance testing\u003c\/li\u003e\n\u003cli\u003e\nUTS7000A-PNM — phase noise measurement\u003c\/li\u003e\n\u003cli\u003e\nUTS7000A-AMK — advanced measurement kit\u003c\/li\u003e\n\u003cli\u003e\nUTS7000A-AMA — analog demodulation (AM\/FM\/PM)\u003c\/li\u003e\n\u003cli\u003e\nUTS7000A-FDD-LTE — LTE FDD demodulation\u003c\/li\u003e\n\u003cli\u003e\nUTS7000A-TDD-LTE — LTE TDD demodulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich preamplifier do I order with the UTS7026A?\u003c\/h3\u003e\n\u003cp\u003eThe UTS7000A-P26 is the matched preamplifier for the 26.5 GHz chassis. Each chassis in the UTS7000A line has its own frequency-matched preamp; using a preamp from a lower-frequency chassis would limit the sensitivity range you can use across the UTS7026A's full span.\u003c\/p\u003e\n\u003ch3\u003eIs the tracking generator included or available as an option?\u003c\/h3\u003e\n\u003cp\u003eThe UTS7000A line does not include a tracking generator on any chassis. For scalar network analysis on a UNI-T signal-analyzer platform with a built-in tracking generator, the UTS5000A series is the alternate instrument.\u003c\/p\u003e\n\u003ch3\u003eCan the real-time analysis bandwidth be expanded after purchase?\u003c\/h3\u003e\n\u003cp\u003eYes — the UTS7026A ships with 40 MHz real-time bandwidth and can be expanded by adding the UTS7000A-B85 (85 MHz), UTS7000A-B160 (160 MHz), or UTS7000A-B255 (255 MHz) bandwidth options. These are field-installable software licenses — purchase, register, and install via the chassis Option Install menu.\u003c\/p\u003e\n\u003ch3\u003eAre the measurement options installed in the factory, or can I license them later?\u003c\/h3\u003e\n\u003cp\u003eThe nine measurement options — 5G NR, VSA, I\/Q, EMI, PNM, AMK, AMA, FDD-LTE, TDD-LTE — install as software licenses on the instrument and can be added at any time after purchase. Each option installs and activates independently.\u003c\/p\u003e\n\u003ch3\u003eDoes the UTS7026A support remote programming and automation?\u003c\/h3\u003e\n\u003cp\u003eYes. The instrument supports SCPI programming over LAN and USB, with the standard interface set including USB 3.0 host, USB 2.0 host, USB-Device, LAN, HDMI, 10 MHz reference In\/Out, external reference input, and two trigger inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTS7026A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Hz – 26.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-time analysis bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 MHz baseline; software-expandable to 85 \/ 160 \/ 255 MHz via B-option licenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplayed average noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−167 dBm\/Hz (with \u003ca href=\"\/products\/uts7000a-p26\"\u003eUTS7000A-P26\u003c\/a\u003e preamp engaged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;−110 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution bandwidth (RBW)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz – 3 MHz (10% steps), 4 \/ 5 \/ 6 \/ 8 \/ 10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 100,001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTraces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.6-inch TFT-LCD touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB 3.0 \/ USB 2.0 host, USB-Device, LAN, HDMI, 10 MHz Ref In\/Out, Ext Ref In, 2× Trigger In, Headphone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking generator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=117\"\u003eUTS7026A Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB2.0 printing cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUTS7000A-AMA — Analog Demodulation Measurement Option\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-AMK — Advanced Measurement Kit Option\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-B160 — 160 MHz Real-Time Analysis Bandwidth License\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-B255 — 255 MHz Real-Time Analysis Bandwidth License\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-B85 — 85 MHz Real-Time Analysis Bandwidth License\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-EMI — EMI Measurement Option\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-FDD-LTE — FDD-LTE Demodulation Analysis Option\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-I\/Q — I\/Q Analyzer Option\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-NR — 5G NR Demodulation Analysis Option\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-P13 — 13.6 GHz Preamplifier Option for UTS7013A\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-P26 — 26.5 GHz Preamplifier Option for UTS7026A\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-P32 — 32 GHz Preamplifier Option for UTS7032A\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-P40 — 40 GHz Preamplifier Option for UTS7040A\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-PNM — Phase Noise Measurement Option\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-TDD-LTE — TDD-LTE Demodulation Analysis Option\u003c\/li\u003e\n  \u003cli\u003eUTS7000A-VSA — Vector Signal Analysis Option\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":48660727398539,"sku":"181200100048X","price":30999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/5387\/6875\/files\/UTS7040A_1_sq.jpg?v=1785212110"},{"product_id":"ute323g-3-ch-high-precision-digital-power-meter-with-gpib","title":"UTE323G 3-Ch High-Precision Digital Power Meter with GPIB","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTE323 Series\u003c\/strong\u003e is a three-channel high-precision digital power meter for three-phase and multi-rail power measurement. Three synchronized measurement channels capture a full three-phase system — or three independent DC\/AC rails — in one instrument, with per-channel and total power, power factor, frequency, energy and harmonics.\u003c\/p\u003e\n\u003cp\u003eIt samples at 300 kSa\/s across a DC to 300 kHz bandwidth and supports every standard wiring configuration (1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A). The UTE323 communicates over RS-232; the UTE323G substitutes GPIB for instrument-bus racks. Measurement firmware and accuracy are identical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — UTE323 Series\u003c\/h2\u003e\n\u003cp\u003eTwo models, one platform. They differ only by communication interface — channel count, accuracy, 300 kSa\/s sampling, wiring modes and harmonic analysis are identical:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:20%\"\u003e\n\u003ccol style=\"width:14%\"\u003e\n\u003ccol style=\"width:40%\"\u003e\n\u003ccol style=\"width:26%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eChannels\u003c\/th\u003e\n\u003cth\u003eWiring Modes\u003c\/th\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE323\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE323G\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ \u003cstrong\u003eGPIB\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eChoose by the interface your test bench uses.\u003c\/p\u003e\n\u003cp\u003eNeed single-phase high-voltage measurement, or a compact panel meter? See the single-channel UTE310 Series (600 V \/ 1000 V single-phase) or the UTE9800+ Series compact power meters — distinct instrument lines for different measurement needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"product-key-features\"\u003e\n\u003cli\u003eThree synchronized measurement channels — full three-phase or three independent rails\u003c\/li\u003e\n\u003cli\u003eWiring modes: 1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/li\u003e\n\u003cli\u003e300 kSa\/s synchronous sampling on all channels\u003c\/li\u003e\n\u003cli\u003eDC to 300 kHz measurement bandwidth\u003c\/li\u003e\n\u003cli\u003ePer-channel and total power, PF, frequency and energy\u003c\/li\u003e\n\u003cli\u003eHarmonic analysis to the 50th order, per channel\u003c\/li\u003e\n\u003cli\u003eEnergy integration (Wh \/ Ah) per channel\u003c\/li\u003e\n\u003cli\u003e5-inch TFT-LCD with simultaneous waveform display\u003c\/li\u003e\n\u003cli\u003eD\/A analog output for external recording\u003c\/li\u003e\n\u003cli\u003eRS-232 standard; GPIB on UTE323G in its place\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTE323 Series Details\u003c\/h2\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Display_sq.jpg?v=1770232639\" alt=\"UTE323 multi-parameter measurement display\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eUTE323 multi-parameter measurement display\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eThree-Phase \u0026amp; Multi-Rail Wiring Modes\u003c\/h3\u003e\n\u003cp\u003eThe UTE323 supports every standard configuration — single-phase two\/three-wire, three-phase three\/four-wire and the 3V3A method. One instrument measures a complete three-phase inverter output, a three-rail DC bus or three independent converters without re-cabling between standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Display_sq.jpg?v=1770232639\" alt=\"UTE323 multi-parameter measurement display\"\u003e\u003cspan class=\"lightbox-caption\"\u003eUTE323 multi-parameter measurement display\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSynchronous 300 kSa\/s Multi-Channel Sampling\u003c\/h3\u003e\n\u003cp\u003eAll three channels sample synchronously at 300 kSa\/s, so phase relationships and per-phase power are measured against a common time base — essential for true three-phase power and imbalance measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Sample_rate_sq.jpg?v=1770232639\" alt=\"300 kSa\/s synchronous sampling on all channels\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003e300 kSa\/s synchronous sampling on all channels\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Sample_rate_sq.jpg?v=1770232639\" alt=\"300 kSa\/s synchronous sampling on all channels\"\u003e\u003cspan class=\"lightbox-caption\"\u003e300 kSa\/s synchronous sampling on all channels\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_wide_bandwidth_sq.jpg?v=1770232639\" alt=\"DC to 300 kHz wide-bandwidth measurement\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eDC to 300 kHz wide-bandwidth measurement\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eDC to 300 kHz Wide-Bandwidth Measurement\u003c\/h3\u003e\n\u003cp\u003eThe wide DC–300 kHz bandwidth keeps switching content and harmonics in the per-phase power calculation, so three-phase inverter and drive measurements reflect the real waveform rather than the fundamental alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_wide_bandwidth_sq.jpg?v=1770232639\" alt=\"DC to 300 kHz wide-bandwidth measurement\"\u003e\u003cspan class=\"lightbox-caption\"\u003eDC to 300 kHz wide-bandwidth measurement\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003ePer-Channel Harmonic Analysis\u003c\/h3\u003e\n\u003cp\u003eHarmonic analysis to the 50th order runs on each channel independently, quantifying per-phase distortion on three-phase rectifier and drive front ends.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_harmonics_sq.jpg?v=1770232639\" alt=\"Harmonic analysis to the 50th order, per channel\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eHarmonic analysis to the 50th order, per channel\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_harmonics_sq.jpg?v=1770232639\" alt=\"Harmonic analysis to the 50th order, per channel\"\u003e\u003cspan class=\"lightbox-caption\"\u003eHarmonic analysis to the 50th order, per channel\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_integral_sq.jpg?v=1770232639\" alt=\"Energy integration (Wh \/ Ah) per channel\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eEnergy integration (Wh \/ Ah) per channel\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003ePer-Channel Energy Integration\u003c\/h3\u003e\n\u003cp\u003eWatt-hour and amp-hour integration accumulate per channel for three-phase efficiency runs and long-duration multi-rail energy profiling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_integral_sq.jpg?v=1770232639\" alt=\"Energy integration (Wh \/ Ah) per channel\"\u003e\u003cspan class=\"lightbox-caption\"\u003eEnergy integration (Wh \/ Ah) per channel\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSimultaneous Waveform Display\u003c\/h3\u003e\n\u003cp\u003eThe 5-inch display shows all channel waveforms together, confirming phase rotation and wiring before the measurement is trusted.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_display_wave_sq.jpg?v=1770232639\" alt=\"Simultaneous waveform display across channels\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eSimultaneous waveform display across channels\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_display_wave_sq.jpg?v=1770232639\" alt=\"Simultaneous waveform display across channels\"\u003e\u003cspan class=\"lightbox-caption\"\u003eSimultaneous waveform display across channels\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_da_sq.jpg?v=1770232639\" alt=\"D\/A analog output for external recording\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eD\/A analog output for external recording\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eD\/A Output\u003c\/h3\u003e\n\u003cp\u003eA D\/A analog output drives a chart recorder or DAQ for long-term trend logging of any measured channel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_da_sq.jpg?v=1770232639\" alt=\"D\/A analog output for external recording\"\u003e\u003cspan class=\"lightbox-caption\"\u003eD\/A analog output for external recording\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eGPIB in Place of RS-232 — UTE323G\u003c\/h3\u003e\n\u003cp\u003eThe UTE323G substitutes a GPIB (IEEE-488) port for RS-232 — it does not add GPIB alongside it. USB and LAN are present on both models, so if you automate over LAN the base UTE323 already covers you; the UTE323G is for racks built on a GPIB instrument bus.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eThree-Phase Inverter \u0026amp; Motor-Drive Efficiency\u003c\/h3\u003e\n\u003cp\u003eMeasure three-phase output power and per-phase imbalance on inverter and motor-drive designs in a single instrument, with synchronous sampling that holds phase relationships true.\u003c\/p\u003e\n\u003ch3\u003eMulti-Rail \u0026amp; Multi-Converter Test\u003c\/h3\u003e\n\u003cp\u003eThree independent channels measure three DC\/AC rails or three converters at once — one instrument instead of three single-channel meters on a multi-output power-electronics bench.\u003c\/p\u003e\n\u003ch3\u003eProduction \u0026amp; QA Test Bench\u003c\/h3\u003e\n\u003cp\u003ePer-channel limits, energy integration and a single RS-232\/GPIB or LAN connection make the UTE323 a compact end-of-line and QA power-test station for small test labs and consultancies.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003cp\u003eUTE-series test cables support safe three-phase connection. Pair the UTE323 with UNI-T programmable sources and electronic loads for a complete three-phase power-characterization bench.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eCan the UTE323 measure a full three-phase system at once?\u003c\/h3\u003e\n\u003cp\u003eYes. Three synchronized channels and the 3P3W \/ 3P4W \/ 3V3A wiring modes measure a complete three-phase system in one instrument.\u003c\/p\u003e\n\u003ch3\u003eCan the three channels measure independent rails instead of one three-phase system?\u003c\/h3\u003e\n\u003cp\u003eYes. The three channels can measure three independent DC\/AC rails or converters simultaneously.\u003c\/p\u003e\n\u003ch3\u003eDoes the UTE323G add GPIB on top of RS-232?\u003c\/h3\u003e\n\u003cp\u003eNo — it substitutes GPIB for RS-232. USB and LAN are on both models; the UTE323G is for GPIB-bus racks.\u003c\/p\u003e\n\u003ch3\u003eDoes each channel measure harmonics?\u003c\/h3\u003e\n\u003cp\u003eYes — per-channel harmonic analysis to the 50th order.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTE323 \/ UTE323G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (synchronous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75mV – 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5mA – 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5W – 12kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300kSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC, 0.1Hz – 300kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1st – 50th\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-inch TFT-LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface (UTE323)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface (UTE323G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ GPIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=116\"\u003eUTE323G Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUT-L0110-BB x3\u003c\/li\u003e\n  \u003cli\u003eUT-L0110-BU x3\u003c\/li\u003e\n  \u003cli\u003eRed\/Black termals x6\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":48660727824523,"sku":"182700300016X","price":3314.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/5387\/6875\/files\/UTE323_1_sq_7267090f-3d7a-43df-82fb-7066bb856830.jpg?v=1785212119"},{"product_id":"mso1254hd-250-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO1254HD 250 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO1254HD is a 250 MHz, 4-channel, 12-bit Mixed Signal Oscilloscope built around UNI-T's native 12-bit ADC architecture (R12™). It samples at 2.5 GSa\/s with 100 Mpts of memory depth per channel and captures waveforms at up to 1,000,000 wfms\/s on a 7-inch capacitive touchscreen powered by Ultra Phosphor 3.0 acquisition technology.\u003c\/p\u003e\n\u003cp\u003eBuilt for switching-supply validation, power-stage characterization, and faster-edge embedded debug, the 12-bit ADC delivers 4,096 vertical levels at the full 250 MHz bandwidth — the resolution that lets you measure mV-scale ripple on a 400 V rail, characterize gate-drive ringing on a GaN\/SiC half-bridge, and read efficiency curves with confidence in the small numbers. Standard protocol decoding covers the full embedded-systems vocabulary (RS-232, UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio) at no additional cost. An optional 16-channel logic analyzer pod adds mixed-signal correlation between control firmware and the analog power stage.\u003c\/p\u003e\n\u003cp\u003eThe 9-in-1 architecture consolidates oscilloscope, logic analyzer (with optional UT-M26 pod), spectrum analyzer, protocol analyzer, digital voltmeter, frequency counter, and power analyzer into one instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e250 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition at 12-bit native resolution for mixed-signal debugging, switching-power analysis, and precision sensor work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/strong\u003e — 4,096 vertical levels at every supported bandwidth — no ERES averaging, no sample-rate trade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 GSa\/s Sample Rate, 100 Mpts\/Channel\u003c\/strong\u003e — Captures fast edges with sufficient timing resolution and holds long records without dropping sample rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1,000,000 wfms\/s Capture Rate\u003c\/strong\u003e — Ultra Phosphor 3.0 intensity-graded display reveals rare anomalies and timing violations that slower scopes miss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Optional Digital Channels\u003c\/strong\u003e — Add mixed-signal debugging with the UT-M26 logic probe pod for time-correlated analog and digital views.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll Protocol Decoding Standard\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding included at no additional cost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e — FFT analysis up to 1 Mpts with peak detection and markers for harmonics, clock spurs, and EMI investigation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements\u003c\/strong\u003e — Time, voltage, frequency, and power-quality parameters with statistical analysis and trend graphs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e — 12 power-quality parameters including efficiency, ripple, and switching loss for switching-supply characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-Inch Capacitive Touchscreen\u003c\/strong\u003e — 1024×600 multi-gesture display with pinch-to-zoom, drag, and gesture navigation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLab-Friendly Connectivity\u003c\/strong\u003e — USB Host\/Device, LAN, AUX Out, HDMI.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T's native 12-bit ADC architecture. It samples at 4,096 quantization levels — sixteen times the vertical detail of a conventional 8-bit oscilloscope — and holds that resolution at the full 250 MHz bandwidth and 2.5 GSa\/s sample rate. There's no ERES averaging step, no sample-rate trade, and no asterisk on the spec sheet.\u003c\/p\u003e\n\u003cp\u003eFor power-electronics validation at full bandwidth, R12 is what lets the MSO1254HD characterize a GaN\/SiC half-bridge in the same bench session as the gate-drive ringing analysis. On a switching-node measurement where 8-bit quantization noise would obscure the µV-scale ripple riding on a 400 V rail, the 12-bit resolution recovers the signal that drives design decisions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_12-bit-screen.png\" alt=\"R12 12-bit ADC architecture at full bandwidth\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNative 12-bit ADC delivers 4,096 vertical levels at full bandwidth\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_12-bit-screen.png\" alt=\"R12 12-bit ADC architecture at full bandwidth\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNative 12-bit ADC delivers 4,096 vertical levels at full bandwidth\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s Acquisition\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 drives the acquisition system at up to 1,000,000 waveforms per second with 256 levels of color intensity mapping. The intensity-graded display shows you signal behavior patterns that a slower scope flattens into solid traces — rare glitches, edge jitter, and occasional protocol-layer anomalies appear as faint trace markings against the dominant signal.\u003c\/p\u003e\n\u003cp\u003eFor intermittent-fault investigation, this is the difference between catching the event in a two-minute capture and waiting for it across an overnight run. The probability of capturing rare anomalies scales with capture rate; one million waveforms per second puts you in the territory where most timing violations show up before lunch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Ultra-Phosphor-3.png\" alt=\"Ultra Phosphor 3.0 intensity-graded display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUltra Phosphor 3.0 reveals rare events with intensity grading\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Ultra-Phosphor-3.png\" alt=\"Ultra Phosphor 3.0 intensity-graded display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUltra Phosphor 3.0 reveals rare events with intensity grading\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eDeep Memory — 100 Mpts Per Channel\u003c\/h3\u003e\n\u003cp\u003e100 Mpts of memory depth per channel maintains the full 2.5 GSa\/s sample rate across wide time-base settings — useful for capturing complete switching cycles in power-electronics validation, or recording an entire startup transient at full resolution. Zoom into any portion of the captured record at full resolution.\u003c\/p\u003e\n\u003cp\u003eFor switching-supply analysis, deep memory captures both the fast-edge transitions and the slow-recovery thermal events in a single acquisition. Soft-start sequences, fault-recovery behavior, and burst-mode operation become visible without piecing together multiple captures.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Protocols.png\" alt=\"Comprehensive protocol decoding included as standard\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eComprehensive protocol decoding included standard\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eAll Protocols Included Standard\u003c\/h3\u003e\n\u003cp\u003eUnlike higher-tier families that charge separately for automotive and industrial protocols, the MSO1000HD platform includes RS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding standard at no additional cost. This makes it one of the most complete embedded-debug platforms in its segment, with no surprise license invoices when an automotive project crosses your bench.\u003c\/p\u003e\n\u003cp\u003eEach decoder correlates the physical-layer signal with the decoded data above the trace, so you can see signal-integrity anomalies and protocol errors in the same acquisition. Search and trigger on data patterns, error conditions, or specific bus events to isolate intermittent communication faults.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Protocols.png\" alt=\"Comprehensive protocol decoding included as standard\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eComprehensive protocol decoding included standard\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eBuilt-In Power Analysis — 12 Parameters\u003c\/h3\u003e\n\u003cp\u003e12 standard power-quality parameters cover efficiency analysis, switching-loss measurement, safe-operating-area visualization, ripple-and-noise characterization, and harmonic content. The measurements run inline on the captured waveform — no scripting, no external software, no PC connection required.\u003c\/p\u003e\n\u003cp\u003eCombined with the 12-bit ADC and 100 Mpts memory, the power-analysis suite handles workloads that previously required a dedicated power analyzer. For switching-supply validation, gate-drive characterization, and small-signal-on-DC-rail measurements, the integrated functions consolidate a multi-instrument workflow into one bench unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 1 Mpts\u003c\/h3\u003e\n\u003cp\u003eFrequency-domain analysis with peak detection, markers, and waterfall display — up to 1 Mpts FFT length. Identify harmonics, clock spurs, switching-frequency content, and EMI contributions without switching to a separate spectrum analyzer or exporting waveform data to PC software.\u003c\/p\u003e\n\u003cp\u003eThe same trace that captured a glitch in the time domain immediately reveals its spectral character on the FFT — useful for chasing down EMI sources during pre-compliance work, or for distinguishing switching-supply harmonics from coupled noise on adjacent rails.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer up to 1 Mpts\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in FFT spectrum analyzer for harmonics and EMI investigation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer up to 1 Mpts\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in FFT spectrum analyzer for harmonics and EMI investigation\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eMixed-Signal Debugging — 16 Optional Digital Channels\u003c\/h3\u003e\n\u003cp\u003e16 optional digital channels add mixed-signal debugging via the UT-M26 logic probe pod. The digital traces display alongside analog channels with full time correlation — see I²C bus traffic and analog ADC output on the same time axis, or watch a control firmware state machine drive the gate signals on a switching power stage.\u003c\/p\u003e\n\u003cp\u003eTime-correlated mixed-signal views are essential for debugging the boundary between firmware and analog hardware. A timing-violation that's invisible on either domain alone often becomes obvious when you can see the digital command and the analog response on the same trace.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e56 Automated Measurements with Statistics\u003c\/h3\u003e\n\u003cp\u003e56 automated measurements cover time, voltage, frequency, and power-quality parameters with statistical analysis (min, max, mean, standard deviation) and trend graphs over long captures. For QA work and bench characterization, the statistical view is more useful than the instantaneous reading — it tells you whether a parameter is drifting, jittering, or holding steady.\u003c\/p\u003e\n\u003cp\u003ePass\/fail mask testing applies user-defined tolerance bands across captured waveforms — useful for rapid go\/no-go testing during bring-up, or for validating board-to-board consistency in small-volume production.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eTouch UI and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 7-inch 1024×600 capacitive touchscreen supports pinch-to-zoom, drag, and gesture navigation across waveforms, menus, and measurement readouts. For students and lab newcomers, the touch interface lowers the barrier to advanced features that are buried behind menu trees on older instruments.\u003c\/p\u003e\n\u003cp\u003eConnectivity covers USB Host, USB Device, LAN, AUX Out, and HDMI. The HDMI output drives an external display for classroom demonstration, and LAN connectivity integrates the instrument into automated test scripts and remote-access workflows.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Engineer (Embedded \/ Hardware Design)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching-Supply Validation\u003c\/strong\u003e — Capture switching transitions and measure mV-scale ripple on multi-hundred-volt rails. The 12-bit ADC at full 250 MHz bandwidth resolves the small-signal-on-large-DC measurements that drive design decisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed-Signal Debug\u003c\/strong\u003e — Time-correlated analog and digital views with the optional UT-M26 logic pod. Track firmware state machines against analog responses on the same trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Investigation\u003c\/strong\u003e — All standard embedded protocols included; no license fees for automotive (CAN, CAN-FD, LIN), industrial (RS-422\/485), or audio buses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity Spot Checks\u003c\/strong\u003e — FFT analysis identifies harmonics, clock spurs, and EMI sources without switching to a separate spectrum analyzer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Electronics Engineer\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching-Loss Characterization\u003c\/strong\u003e — Built-in power-analysis measurements run inline on the captured waveform — no scripting, no external software. Quantify gate-drive losses, conduction losses, and switching transient energy in one capture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft-Start and Fault-Recovery Capture\u003c\/strong\u003e — 100 Mpts deep memory records the entire transient at sample-rate resolution; no piecing together multi-pass captures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple and Noise on DC Rails\u003c\/strong\u003e — The 12-bit ADC resolves µV-scale ripple on multi-hundred-volt DC rails — measurements that an 8-bit scope fundamentally cannot make.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic Content Investigation\u003c\/strong\u003e — Built-in FFT to 1 Mpts identifies switching-frequency content, harmonics, and coupled noise sources.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO1254HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e4 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUT-M26 — 16-channel logic probe pod for mixed-signal debugging\u003c\/li\u003e\n\u003cli\u003e\nUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003e\nUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003e\nUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003e\nUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed an integrated signal generator and Bode plot analysis? See the MSO1254HD-S. Need a 150 MHz value-tier option? See the MSO1154HD.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat protocols are included with the MSO1254HD?\u003c\/p\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding are included standard at no additional cost. All supported protocols are available out of the box — no optional licenses required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the advantage of native 12-bit resolution?\u003c\/p\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I add digital channels for mixed-signal debugging?\u003c\/p\u003e\n\u003cp\u003eYes. The UT-M26 logic probe pod adds 16 digital channels for time-correlated analog and digital views.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes this model include a signal generator?\u003c\/p\u003e\n\u003cp\u003eNo. For an integrated 1-channel 25 MHz AWG with Bode plot analysis, see the MSO1254HD-S.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the MSO1254HD compare to the higher-bandwidth UPO2000HD or MSO3000HD scopes?\u003c\/p\u003e\n\u003cp\u003eThe MSO1000HD platform shares the same R12™ 12-bit ADC architecture, Ultra Phosphor 3.0 acquisition, and standard-included protocol decoding as the UPO2000HD and MSO3000HD families. The differences are bandwidth (150–250 MHz here vs 100–500 MHz on UPO2000HD and 350–1000 MHz on MSO3000HD), capture rate (1,000,000 wfms\/s here vs 1,500,000 wfms\/s on MSO3000HD), and the front-panel form factor. For embedded prototyping and mid-tier power-electronics work, the MSO1000HD platform delivers the same architectural advantages at a lower price point.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the firmware field-upgradable?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003ePart of the MSO1000HD oscilloscope series. See the series page to compare bandwidth and channel options across the lineup.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Optional Digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-inch capacitive touchscreen, 1024×600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, video, runt, slope, zone, setup\/hold, and more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — up to 1 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 with statistics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional 16-channel via UT-M26 pod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host \/ USB Device \/ LAN \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=111\"\u003eMSO1254HD Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":48660728905867,"sku":"181100300120X","price":809.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/5387\/6875\/files\/MSO1254HD-S_1_sq.jpg?v=1785212141"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/5387\/6875\/collections\/UTi740H_-2_sq_7248bc6b-c608-475c-b064-34dcc512581e.jpg?v=1785212525","url":"https:\/\/www.kalye.shop\/collections\/electronic-tools-gadgets.oembed","provider":"kaLye ","version":"1.0","type":"link"}